Troubleshooting – Gorman-Rupp Pumps 16D60-F3L 1270259 thru 1318306 User Manual
Page 18
OM--05534
10 SERIES
TROUBLESHOOTING
PAGE D -- 1
TROUBLESHOOTING --- SECTION D
Review all SAFETY information in Section A.
Before attempting to open or service the
pump:
1. Familiarize yourself with this manual.
2. Switch off engine ignition and dis-
connect the positive battery cable to
ensure that the pump will remain in-
operative.
3. Allow the pump to completely cool if
overheated.
4. Check the temperature before open-
ing any covers, plates, or plugs.
5. Close the suction and discharge
valves.
6. Vent the pump slowly and cautiously.
7. Drain the pump.
Table 1. Trouble Shooting Chart
TROUBLE
POSSIBLE CAUSE
PROBABLE REMEDY
PUMP FAILS TO PRIME
Not enough liquid in casing.
Suction check valve contaminated or
damaged.
Air leak in suction line.
Lining of suction hose collapsed.
Leaking or worn seal or pump gas-
ket.
Suction lift or discharge head too
high.
Strainer clogged.
Add liquid to casing. See
PRIMING.
Clean or replace check valve.
Correct leak.
Replace suction hose.
Check pump vacuum. Replace leak-
ing or worn seal or gasket.
Check piping installation and install
bypass line if needed. See
INSTAL-
LATION.
Check strainer and clean if neces-
sary.
PUMP STOPS OR FAILS
TO DELIVER RATED
FLOW OR PRESSURE
Air leak in suction line.
Lining of suction hose collapsed.
Correct leak.