Gorman-Rupp Pumps U4B65S-B 1298951 and up User Manual
Page 15
OM-05667
SUPER U SERIES
PAGE B - 8
INSTALLATION
Adjusting the alignment in one direction
may alter the alignment in another direc
tion. check each procedure after altering
alignment.
Coupled Drives
When using couplings, the axis of the power
source must be aligned to the axis of the pump
shaft in both the horizontal and vertical planes.
Most couplings require a specific gap or clearance
between the driving and the driven shafts. Refer to
the coupling manufacturer's service literature.
Align spider insert type couplings by using calipers
to measure the dimensions on the circumference
of the outer ends of the coupling hub every 90
_.
The coupling is in alignment when the hub ends
are the same distance apart at all points (see Fig
ure 4).
Figure 4. Aligning Spider‐Type Couplings
Figure 5. Aligning Non‐Spider Type Couplings
Align non‐spider type couplings by using a feeler
gauge or taper gauge between the coupling halves
every 90
_. The coupling is in alignment when the
hubs are the same distance apart at all points (see
Figure 5).
Check parallel adjustment by laying a straightedge
across both coupling rims at the top, bottom, and
side. When the straightedge rests evenly on both
halves of the coupling, the coupling is in horizontal
parallel alignment. If the coupling is misaligned,
use a feeler gauge between the coupling and the
straightedge to measure the amount of misalign
ment.
Drive Belts
When using drive belts, the power source and the
pump must be parallel. Use a straightedge along
the sides of the pulleys to ensure that the pulleys
are properly aligned (see Figure 6). In drive sys
tems using two or more belts, make certain that the
belts are a matched set; unmatched sets will cause
accelerated belt wear.
MISALIGNED:
SHAFTS
NOT PARALLEL
MISALIGNED:
SHAFTS
NOT IN LINE
ALIGNED: SHAFTS
PARALLEL AND
SHEAVES IN LINE
Figure 6. Alignment of V‐Belt Driven Pumps
Tighten the belts in accordance with the belt manu
facturer's instructions. If the belts are too loose,
they will slip; if the belts are too tight, there will be
excessive power loss and possible bearing failure.
Select pulleys that will match the proper speed ra
tio; overspeeding the pump may damage both
pump and power source.
Do not operate the pump without the
guard in place over the rotating parts
.
exposed rotating parts can catch cloth
ing, fingers, or tools, causing severe in
jury to personnel.