beautypg.com

Gorman-Rupp Pumps U6B60S-B 1289612 and up User Manual

Page 39

background image

OM-05669

SUPER U SERIES

MAINTENANCE & REPAIR

PAGE E - 16

holes in the back cover plate. Secure the locking
collars to the back cover plate with the hardware
(42 and 43). Install the two remaining back cover
nuts snugly against the adjusting screws.

Remove the first two back cover nuts from their
studs. Turn the adjusting screws clockwise until
they engage the pump casing. Install the locking
collars and hardware (46 and 47). Reinstall the
back cover nuts.

Be sure the wear plate does not scrape against the
impeller.

Over time it may be necessary to repeat the adjust­
ment process to compensate for normal wear be­
tween the impeller and wear plate. When all of the
adjustment has been used on the back cover side
of the pump, an additional 0.125 inch (3,2 mm) of
adjustment may be obtained by removing the ro­
tating assembly adjusting shims (10).

Allow an installed pump to completely cool before
draining liquid from the pump casing. Remove the
back cover. Remove the rotating assembly adjust­
ing shims, then reinstall the hardware securing the
rotating assembly to the pump casing. Perform the
back cover adjustment procedure described
above to obtain the proper face clearance.

PRESSURE RELIEF VALVE
MAINTENANCE

(Figure 1)

The back cover is equipped with a pressure relief
valve (37) to provide additional safety for the pump
and operator (refer to Liquid Temperature And
Overheating
in OPERATION).

It is recommended that the pressure relief valve as­
sembly be replaced at each overhaul, or any time
the pump overheats and activates the valve. Never
replace this valve with a substitute which has not
been specified or provided by the Gorman‐Rupp
Company.

Periodically, the valve should be removed for in­
spection and cleaning. When reinstalling the relief
valve, apply `Loctite Pipe Sealant With Teflon No.
592', or equivalent compound, on the relief valve
threads. Position the valve as shown in Figure 1
with the discharge port pointing down.

Final Pump Assembly

(Figure 1)

Install the shaft key (19, Figure 2) and reconnect
the power source. Be sure to install any guards
used over the rotating members.

Do not operate the pump without the
guards in place over the rotating parts.
Exposed rotating parts can catch cloth­
ing, fingers, or tools, causing severe in­
jury to personnel.

Install the suction and discharge lines and open all
valves. Make certain that all piping connections are
tight, properly supported and secure.

Be sure the pump and power source have been
properly lubricated, see LUBRICATION.

Remove the fill cover assembly (16) and fill the
pump casing with clean liquid. Reinstall the fill
cover and tighten it. Refer to OPERATION, Section
C, before putting the pump back into service.

LUBRICATION

Seal Assembly

(Figure 2)

Check the oil level regularly through the sight
gauge (20)

and maintain it at the middle of the

gauge. When lubrication is required, add SAE No.
30 non‐detergent oil through the hole for the
vented plug (11). Clean and reinstall the vented
plug. Maintain the oil at this level.

NOTE

The white reflector in the sight gauge must be posi­
tioned horizontally to provide proper drainage.

Bearings

(Figure 2)

The bearing housing was fully lubricated when
shipped from the factory. Check the oil level regu­
larly through the sight gauge (21)

and maintain it at

This manual is related to the following products: