background image

OM-05669

SUPER U SERIES

MAINTENANCE & REPAIR

PAGE E - 12

SEAL PLATE

O‐RINGS

IMPELLER

OIL SEAL

STATIONARY

STATIONARY

ROTATING

DRIVE BAND

BELLOWS

IMPELLER SHIMS

IMPELLER

SPRING

RETAINER

ELEMENT

ELEMENT

SEAT

SHAFT

SHAFT SLEEVE

SLEEVE

O‐RING

Figure 6. 46513-154 Cartridge Seal Assembly

This seal is not designed for operation at
temperatures above 160

_

F (71

_

C). Do not

use at higher operating temperatures.

If the seal plate was removed, install the seal plate
gasket (3). Position the seal plate over the shaft
and secure it to the bearing housing with the hard­
ware (4 and 5).

To prevent damaging the shaft sleeve O‐ring (9) on
the shaft threads, stretch the O‐ring over a piece of
tubing 1‐1/2 I.D. x 1‐7/8 O.D. x 2‐inches long (38
mm x 48 mm x 51 mm). Slide the tube over the shaft
threads, then slide the O‐ring off the tube and onto
the shaft. Remove the tube, and continue to slide
the O‐ring down the shaft until it seats against the
shaft shoulder.

When installing a new cartridge seal assembly,
remove the seal from the container, and remove

the mylar storage tabs, if so equipped, from be­
tween the seal faces.

Most new cartridge seal assemblies are
equipped with mylar storage tabs between
the seal faces. These storage tabs must be
removed before installing the seal.

Lubricate the external stationary seat O‐ring with
light oil. Slide the seal assembly onto the shaft until
the external stationary seat O‐ring engages the
bore in the seal plate.

Clean and inspect the impeller as described in Im­
peller Installation and Adjustment
. Install the full
set of impeller shims (8) provided with the seal, and
screw the impeller onto the shaft until it is seated
against the seal (see Figure 7).