beautypg.com

Gorman-Rupp Pumps 82D-GX160 987917 and up User Manual

Page 15

background image

OM−03790

80 SERIES

OPERATION

PAGE C − 3

STOPPING

Never halt the flow of liquid suddenly. If the liquid
being pumped is stopped abruptly, damaging
shock waves can be transmitted to the pump and
piping system. Close all connecting valves slowly.

On engine driven pumps, reduce the throttle
speed slowly and allow the engine to idle briefly be-
fore stopping.

If the application involves a high discharge
head, gradually close the discharge throt-
tling valve before stopping the pump.

After stopping the pump, remove the spark plug
wire to ensure that the pump will remain inopera-
tive.

Cold Weather Preservation

In below freezing conditions, drain the pump to

prevent damage from freezing. Also, clean out any

solids by flushing with a hose. Operate the pump

for approximately one minute; this will remove any

remaining liquid that could freeze the pump rotat-

ing parts. If the pump will be idle for more than a

few hours, or if it has been pumping liquids con-

taining a large amount of solids, drain the pump,

and flush it thoroughly with clean water. To prevent

large solids from clogging the drain port and pre-

venting the pump from completely draining, insert

a rod or stiff wire in the drain port, and agitate the

liquid during the draining process. Clean out any

remaining solids by flushing with a hose.

This manual is related to the following products: