Gorman-Rupp Pumps PA10A60-4045H-ESP 1423416 thru 1485219 User Manual
Page 38
PA SERIES
OM-06351
MAINTENANCE & REPAIR
PAGE E - 18
for use in lifting the pump assembly
only. Suction and discharge hoses and
piping must be removed from the pump
before lifting. If chains or cables are
used to lift pump components, make
certain that they are positioned so as
not to damage the pump, and so that the
load will be balanced.
Use only replacement parts provided or
approved by Gorman‐Rupp. Use of non‐
authorized parts may result in damage to
the equipment and/or injury to personnel
and will invalidate the warranty.
Priming Chamber Removal And Disassembly
(Figure 6)
Disconnect the air discharge tubing from the prim
ing chamber assembly (1). Support the priming
chamber assembly using a sling and a suitable lift
ing device. Remove the hardware (6 and 7) and
separate the priming chamber assembly, gasket
(8) and baffle (9) from the spool (7, Figure 5).
(Figure 7)
Remove the hardware (2 and 3) securing the prim
ing valve (1) to the priming chamber (5). Carefully
lift the valve components from the priming cham
ber. Remove the gasket (4) and clean the mating
surfaces.
If the priming valve float is stuck or the strainer (6) is
clogged, it can usually be cleaned without further
disassembly.
The only serviceable part of the priming valve is the
orifice button (not shown). If liquid continues to by
pass through the priming chamber after adjusting
the orifice button (see Priming Chamber Reas
sembly and Installation for adjustment), the but
ton may require replacement. To replace the orifice
button, remove one of the “e‐clips” from the pivot
pin closest to the orifice button and remove the piv
ot pin. This will allow the linkage to be raised high
enough to access the orifice button.
Remove the hex nut and lockwasher securing the
orifice button to the linkage bar and unscrew the
orifice button from the linkage bar.
Discharge Check Valve Disassembly
(Figure 2)
The flapper and cover O‐ring are the only service
able parts of the check valve (53). If the flapper re
quires replacement, remove the hardware secur
ing the cover to the check valve body. Separate the
cover and remove the cover O‐ring and flapper.
Suction Spool Flange Removal
(Figure 5)
Before attempting to disassemble the pump, re
move the lowermost pipe plug (30, Figure 6) from
the pump casing and drain the pump. Clean and
reinstall the pipe plug.
Disconnect the suction piping from the suction
spool flange (7).
Support the suction spool flange using a suitable
hoist and sling. Disengage the hardware (not
shown) securing the suction spool flange to the
base.
Use lifting and moving equipment in
good repair and with adequate capacity
to prevent injuries to personnel or dam
age to equipment. If slings or chains are
used to move the pump or components,
make sure that the load is balanced;
otherwise serious personal injury or
death could result. Suction and dis
charge hoses and piping must be re
moved from the pump before lifting.
Remove the hardware (4, 5 and 6) and separate
the suction spool flange and gasket (3) from the
pump.