Troubleshooting - section d – Gorman-Rupp Pumps 83A1-L100EE-X 1512373 and up User Manual
Page 16
TROUBLE
POSSIBLE CAUSE
PROBABLE REMEDY
PUMP FAILS TO
PRIME
Strainer clogged.
Check strainer and clean if neces
sary.
Suction lift or discharge head too high.
Check piping installation and install
bypass line if needed. See INSTAL
LATION.
Leaking or worn seal or pump gasket.
Check pump vacuum. Replace
leaking or worn seal or gasket.
Lining of suction hose collapsed.
Replace suction hose.
Air leak in suction line.
Correct leak.
Not enough liquid in casing.
Add liquid to casing. See
PRIMING.
Suction check valve contaminated or
damaged.
Clean or replace check valve.
Suction check valve or foot valve
clogged or binding.
Clean valve.
Pump speed too slow.
Check engine output; consult en
gine operation manual.
OM-05133
80 SERIES
TROUBLESHOOTING
PAGE D - 1
TROUBLESHOOTING - SECTION D
Review all Safety information in Section A.
Before attempting to open or service the
pump:
1. Familiarize yourself with this
manual.
2. Shut down the engine and take pre
cautions to ensure that the pump
will remain inoperative.
3. Allow the pump to completely cool
if overheated.
4. Check the temperature before
opening any covers, plates, or
plugs.
5. Close the suction and discharge
valves.
6. Vent the pump slowly and cau
tiously.
7. Drain the pump.