Iv. sp101 specifications, V. sp102 specifications, Vi. maintenance – Xylem SP102 Solar Panel User Manual
Page 5: Iv. sp101, Specifications, V. sp102, Maintenance

Global Water
800-876-1172
• globalw.com
IV.
SP101 Specifications
Sensing element:
Output:
>120mA@>17
Volts
Power:
>1.9W
Operating Temperature: -40°C to +80°C (-40°F to 176°F)
Size of Panel:
6.25"H x 9.25"W x 1”D
Weight:
3.4 lb. w/mounting bracket
Connector Cable Length: 120”
V.
SP102 Specifications
Sensing element:
Output:
>300 mA@>16.5 Volts
Power:
>4.9W
Operating Temperature: -40°C to +80°C (-40°F to 176°F)
Size of Panel:
10"H x 12"W x 2.25”D with junction box
Weight:
4.6 lb. w/mounting bracket
Connector Cable Length: None
VI.
Maintenance
a. Global Water recommends inspecting the panel once every 6 months
to verify the connections are still good and there is no corrosion on the
contacts.
b. The panel should be cleaned periodically. Dirt and dust will reduce the
power output of the panel. Gently clean the surface with a soft cloth or
sponge using water and a mild detergent. Do not scrub the surface
using a brush or abrasive material this may damage the face. Please
take care, since the unit generates direct current and the potential for
shocks is present.
- 5 -