beautypg.com

Xylem WL450 ALL STAINLESS STEEL WATER LEVEL TRANSMITTERS User Manual

Quick reference, Wl450 level sensor

background image

AIL001-QS-WL450Rev-E.doc

Quick Reference

WL450 Level Sensor

Rev. E

Pressure Transducer for measuring water level,

Pressure sensor

with analog 4-20mA output and Barometric

Pressure compensation.


Basic Handling & Operation:

Ensure that the cable is handled & stored with large loops and NOT
KINKED (which blocks the barometric pressure compensation tube).

Big Loops, No Kinks


Installation Notes:

Groundwater Installations:

• Terminate cable into a dry enclosure – to avoid moisture entering
pressure compensation tube in cable.

• Secure the Sensor Cable:
Ensure that the cable is clamped securely
to topside hardware BEFORE deploying sensor down well.
DO NOT EXCEED THE MAXIMUM RATED DEPTH OF THE SENSOR
OR IRREPARABLE DAMAGE TO THE SENSOR MAY OCCUR!

It is not necessary to locate the sensor at the well's bottom – merely
below the lowest likely water level.

Avoid cable entanglements by installing sensor at least ten feet
above the well pump
.


Open-Channel Installations:

Keep debris, silt or mud away from
sensor (eg: Open Channel
installations) by housing sensor in
perforated conduit or wellscreen.


• Use Long-Sweep Elbows
(PVC conduit fittings) to
ease cable deployment through conduit for riverbank
monitoring of flow / level in open channels.

Vent cable

in dry box

Clamp Cable

Securely

sensor

pump

Enclosure

Sensor:
10 ft ( =3m )
above pump