beautypg.com

Collect data, Activate modem press test button – Xylem STORM Central User Manual

Page 10

background image

COLLECT DATA

CELL MODEM

8

The Timeout (sec) field allows the various timeouts within the modem initialization scripts to be

altered. Generally, a 10 second timeout is enough for areas with good signal strength. However, it

may be necessary to increase the timeout period (perhaps to 15 or 20 seconds) in order to allow

the modem more time to initialize and find a signal. It may be wise to test the connection a couple
of times with various timeouts to determine the best setting for your particular area.

For a modem to successfully

communicate, it must first be activated.

Modems supplied by WaterLOG are

deactivated prior to shipping to prevent

unwanted charges to your account. If the

cellular service was purchased through

WaterLOG Sales, contact your WaterLOG

Sales Representative via one of the

methods mentioned above and request

activation of your modem. Activation

takes just a few minutes.

Note: If you have your own cellular service, be
sure to have it activated. If using a GSM service
provider, also have your SIM card installed, and
GSM Settings specified.

Once the modem has been configured,

press the ‘Begin Test’ button under

the Connection Information section to

test the modem settings. The modem

will power up and initialize. It will then

check its activation status by testing its

Signal Strength, retrieving its Network

Status, and looking for an IP Address.

The Connection Status will update

as it performs its tests. If all settings

are correct and the connection was

successful, the IP address field will be

filled in (e.g. 10.204.1.161). An IP address
indicates the modem setup is complete.

Activate Modem

Press Test Button