Xv. connections – Xylem WQ-FDO Sensor and GL500-7-2 Data Logger User Manual
Page 30
Global Water
800-876-1172
• globalw.com
- 30 -
XV. Connections:
Left Connector:
P2+
Pulse channel 2 +, connected to VBAT
P2 IN
Pulse channel 2 pulse input
P1+
Pulse channel 1 +, connected to VBAT
P1 IN
Pulse channel 2 pulse input
SMP+
Sample-On-Demand +, VBAT
SMPL
Sample-On-Demand pulse input
GND
Spare Ground
GND
Spare Ground
VBAT
Spare positive battery connection
VBAT
Spare positive battery connection
GND
Negative battery connection
VBAT
Positive battery connection
Right Connector:
V+
Switched sensor power
CH1
Analog channel 1 input
GND
Sensor ground
V+
Switched sensor power
CH2
Analog channel 2 input
GND
Sensor ground
V+
Switched sensor power
CH3
Analog channel 3 input
GND
Sensor ground
V+
Switched sensor power
CH4
Analog channel 4 input
GND
Sensor ground
V+
Switched sensor power
CH5
Analog channel 5 input
GND
Sensor ground
V+
Switched sensor power
CH6
Analog channel 6 input
GND
Sensor ground
V+
Switched sensor power
CH7
Analog channel 7 input
GND
Sensor ground
GND
Spare ground connection