beautypg.com

Xylem WQ-FDO Sensor and GL500-7-2 Data Logger User Manual

Page 10

background image

Global Water

800-876-1172

globalw.com

- 10 -

Sample initialization text file:

This is for reference and applies to

an external US Robotics modem only.

ATM1 ; speaker off when connects

AT&B1 ; fixed serial port rate

AT&D2 ; normal DTR

AT&H1&R2 ; h/w flow control

Connect 19200

AT&I0 ; disable s/w flow control

AT&K0 ; disable compression

AT&M4 ; normal error control

Select the COM port for your modem

and the baud rate. Type in the phone

number or select it from the list of pre-

stored numbers. If necessary, click the “Use Initialization File” box and use

the browse button to search for the initialization text file for your modem. Click

“Connect” and the software will dial out, showing the status screen shown above.

Once a connection is established, “Connect” will appear for a few seconds along with

the baud rate of the connection. After connecting, the normal Global Logger screen

will appear and operate exactly as if a direct connection was made. All options and

features work the same but at a reduced communication speed.

When connecting the GL500 Data Logger to an external modem, a special cable is

required. Wiring diagrams are provided at the end of this manual and pre-wired

cables are available from Global Water. The remote modem is configured by setting

DIP switches. They should be set to auto-answer on, DTR Normal, carrier detect

normal and smart mode. Global Water can provide external modems and interface

cables at an additional cost if requested. Contact our sales department for more

information.

It may not be necessary to use an initialization string to configure the host modem

but if problems arise the modem should be set with software handshaking off (Xoff),

DTR normal, fixed baud rate, compression off and error correction on. This

configuration is done by building an initialization file using the standard AT

commands and loading it into the connection screen. Global Water suggests that

you test the modems operation before installing in the field.