XI.

Main Screen:


The main screen is where the status and option menus are accessed. The FL16
data logger will continue to log at normal intervals while connected to the Global

Logger software. While connected, the logger will draw an addition current from the
power supply of 5-10mA so it is advised that, if you plan to not access the logger for
extended periods of time, you disconnect to increase battery life. Interface cables
may remain connected. To disconnect, click on the “Disconnect” button. This label

on this button will change to “Connect” and clicking on it will return you to the
connection screen as previously discussed.
















The functions and information in this screen are discussed in the following sections.
Note that channel one always displays level, the second channel shows water
temperature and channel 3 records battery voltage. Flow is always displayed in the

channel to the right of battery voltage. Water velocity is displayed next to flow when
using the Manning’s Equation mode only. Flow parameters are shown on the right.