Declaration of conformity – YSI Pro1020 User Manual
Page 24
40
41
Part Number
Description
605202
Galvanic DO Sensor
605203
Polarographic Sensor
603059
Flow cell, 203 ml
603056
Flow cell mounting spike
603075
Carrying case, large, soft-sided
603162
Carrying case, small, soft-sided (holds instrument
and up to a 4 meter cable/probe assembly
603074
Carrying case, hard-sided
603069
Belt clip for clipping instrument onto belt
063517
Ultra clamp for instrument for clamping
instrument to lab counter or other surface
063507
Tripod for instrument
603062
Cable management kit, included with all cables
longer than 1 meter
605978
Cable weight, 4.9 oz, stackable
603070
Shoulder strap
003821
pH 4 Buffer, box of 6 pints
003822
pH 7 Buffer, box of 6 pints
003823
pH 10 Buffer, box of 6 pints
603824
pH Buffer, assorted case, 2 pints each of buffer
4, 7 and 10
605306
5908 Cap membrane kit, 1.25 mil PE (6 each),
includes electrolyte (yellow cap). Used with
Polarographic sensor.
605307
5909 Cap membrane kit, 2 mil PE (blue cap, 6
each), includes electrolyte (blue cap). Used with
Polarographic sensor.
605913
5913 Cap membrane kit, 1.25 mil PE (yellow cap,
6 each), includes electrolyte. Used with Galvanic
sensor.
605914
5914 Cap membrane kit, 2 mil PE (blue cap, 6
each), includes electrolyte. Used with Galvanic
sensor.
*All cables include a temperature sensor. The pH or ORP and Dissolved
Oxygen sensors are sold separately.
D E C L A R A T I O N O F C O N F O R M I T Y
The undersigned hereby declares on behalf of the named manufacturer
under our sole responsibility that the listed product conforms to the
requirements for the listed European Council Directive(s) and carries the
CE mark accordingly.
Manufacturer:
YSI Incorporated
1725 Brannum Lane
Yellow Springs, OH 45387
USA
Product Name:
Pro1020 Water Quality Instrument
Model Numbers
Instrument/
Accessory:
Pro1020 (6051020)
Probe/Cable
Assemblies:
6051020-1, -4, -10, -20, and -30
Conforms to the following:
Directives:
EMC 2004/108/EC
RoHS 2011/65/EU
WEEE 2012/19/EU
Harmonized
Standards:
• EN61326-1:2006 (IEC 61326-1:2005)
• IEC 61000-3-2:2005
• IEC 61000-3-3:2005
Supplementary
Information:
All performance met the operation
criteria as follows:
1. ESD, IEC 61000-4-2:2001
2. Radiated Immunity, IEC 61000-4-3:2006
3. Electrical Fast Transient (EFT), IEC 61000-
4-4:2004, +Corr. 1:2006 + Corr. 2:2007
4. Radio Frequency, Continuous Conducted
Immunity, IEC61000-4-6:2006
5. IEC 6100-4-8:2001
Authorized EU
Representative
Xylem Analytics UK Ltd
Unit 2 Focal Point, Lacerta Court, Works Road
Letchworth, Hertfordshire, SG6 1FJ UK
Signed: Lisa M. Abel
Date: 23 January 2014
Title: Director of Quality