8. Maintenance/Disassembly
Pumps are subject to wear. If the pump is blocked or grinding noises are audible, check
the pump and replace it if necessary. Procedure:
- Disconnect pump from the mains.
- Close the connection lines.
- Loosen the union nut and remove the motor (Residual water
may leak out of the rotor cavity. Prevent the electrical
connection to the pump from getting wet.).
When replacing non-LOWARA motors, use the additionally included flat seal. The groove
for holding the flat seal in non-LOWARA pump housings has an additional ridge that can
cause leakage when used with an O-ring seal.
9. Troubleshooting
Work on electrical parts may only be performed by authorized
specialists.
Problem Cause
Solution
Pump not running
- Not connected or
connected incorrectly
- Pump too hot, dry
operation- or overheating
protection active
- Pump blocked
- Connect correctly
- Allow to cool, pump
restarts automatically
- See section 8
“Maintenance/Disassembly”
Pump is noisy
- Not thoroughly bled
- Foreign objects in pump
- Worn bearing
- See section 7.2 “Getting
started”
- See section 8
“Maintenance/Disassembly”
- Replace pump
Malfunctioning pumps can be returned to the manufacturer‘s address. The manufacturer
will refuse to accept packages with unpaid shipping or invoices for repair. The
manufacturer grants a two-year guarantee under the condition of correct installation and