S-Drive Motor Overload Settings

Motor Overload Setting

Supply

Frame

Model

100% 95% 90% 85% 80% 70% 50%

*

40%

*

Voltage

Size

Number

1

SPD20050

17.8 16.9 16.0 15.1 14.2 12.5 8.9 7.1

SPD20050F

SPD20075

26.4 25.1 23.8 22.4 21.1 18.5 13.2 10.6

2

SPD20075F

SPD20100

37.0 35.2 33.3 31.5 29.6 25.9 18.5 14.8

SPD20100F

208/230

SPD20150

47.4 45.0 42.7 40.3 37.9 33.2 23.7 19.0

3

SPD20150F

SPD20200

60.6 57.6 54.5 51.5 48.5 42.4 30.3 24.2

SPD20200F

SPD20250

76.0 72.2 68.4 64.6 60.8 53.2 38.0 30.4

4

SPD20250F

SPD20300

94.0 89.3 84.6 79.9 75.2 65.8 47.0 37.6

SPD20300F

SPD40050

8.9 8.5 8.0 7.6 7.1 6.2 4.5 3.6

1

SPD40050F

SPD40075

13.2 12.5 11.9 11.2 10.6 9.2 6.6 5.3

SPD40075F

SPD40100

18.5 17.6 16.7 15.7 14.8 13.0 9.3 7.4

SPD40100F

460

2

SPD40150

23.7 22.5 21.3 20.1 19.0 16.6 11.9 9.5

SPD40150F

SPD40200

30.3 28.8 27.3 25.8 24.2 21.2 15.2 12.1

SPD40200F

SPD40250

37.5 35.6 33.8 31.9 30.0 26.3 18.8 15.0

3

SPD40250F

SPD40300

47.0 44.7 42.3 40.0 37.6 32.9 23.5 18.8

SPD40300F

* Only use 50% and 40% settings for 1Ø input

Xylem Inc.

www.xyleminc.com