Xylem IM103 R03 5 and Larger Submersible Pump User Manual
Page 27

27
Trifásico, 4" Motores - Datos Eléctricos, 60 Hertz, 3450 RPM
Carga completa Factor de servicio Rotor bloqueado
amperios
Línea a línea
resistencia
CentriPro #
HP
kW
Voltios
SF
Amps
Watts
Amps
Watts
M30430
3
2.2
200
1.15
10.9
2890
12.0
3290
71
0.9-1.3
M50430
5
3.7
1.15
18.3
4850
20.2
5515
113
0.4-0.8
M75430
7.5
5.5
1.15
27.0
7600
30.0
8800
165
0.5-0.6
M30432
3
2.2
230
1.15
9.2
2880
10.1
3280
58.9
1.3-1.7
M50432
5
3.7
1.15
15.7
4925
17.5
5650
93
.85-1.25
M75432
7.5
5.5
1.15
24
7480
26.4
8570
140
.55-.85
M30434
3
2.2
460
1.15
4.8
2920
5.3
3320
30
5.9-6.5
M50434
5
3.7
1.15
7.6
4810
8.5
5530
48
3.58-4.00
M75434
7.5
5.5
1.15
12.2
7400
13.5
8560
87
1.9-2.3
M100434
10
7.5
1.15
15.6
9600
17.2
11000
110
1.8-2.2
M30437
3
2.2
575
1.15
3.7
2850
4.1
3240
21.1
9.4-9.7
M50437
5
3.7
1.15
7.0
5080
7.6
5750
55
3.6-4.2
M75437
7.5
5.5
1.15
9.1
7260
10.0
8310
55
3.6-4.2
Generación II - 3-Alambre, Monofásico, 4" Motores - Datos Eléctricos, 60 Hertz, 3450 RPM
Carga
completa
Factor de
servicio
Rotor
bloquea-
do am-
perios
Resistencia
de devanado Rectángulo
de control
requerido
1
Tipo
Número
de
orden
HP
kW Voltios
SF
Amps Watts Amps Watts
Prin-
cipal
(B-Y)
Ar-
ranque
(R-Y)
3-Alambre
con CSCR
(CR) o el
rectángulo
de control
magnético
del
contactor
(bujía
métrica)
M30412
3
2.2
230
1.15
Y – 14.3
B – 12.0
R – 5.7
3170
Y – 16.5
B – 13.9
R – 5.6
3620
76
1.1 -
1.4
2.0 -
2.5
CB30412CR or
CB30412MC
M50412
5
3.7
Y – 24.0
B – 19.1
R – 10.2
5300
Y – 27.0
B – 22.0
R – 10.0
6030
101
.62 -
.76
1.36 -
1.66
CB50412CR or
CB50412MC
¹ Un rectángulo de control de CSCR con un sufijo del CR se puede substituir por una conclusión magnética del modelo del MC.
Y = amarillo, B = negro, R = rojo