beautypg.com

Xylem IM084 R05 SSH-C and SSH-F User Manual

Page 3

background image

3

SAFETY INSTRUCTIONS

TO AVOID SERIOUS OR FATAL PERSONAL

INJURY OR MAJOR PROPERTY DAMAGE, READ

AND FOLLOW ALL SAFETY INSTRUCTIONS IN

MANUAL AND ON PUMP.
THIS MANUAL IS INTENDED TO ASSIST IN THE

INSTALLATION AND OPERATION OF THIS UNIT

AND MUST BE KEPT WITH THE PUMP.

This is a SAFETY ALERT SYMBOL.

When you see this symbol on the pump

or in the manual, look for one of the fol-

lowing signal words and be alert to the

potential for personal injury or property

damage.
Warns of hazards that WILL cause

serious personal injury, death or major

property damage.
Warns of hazards that CAN cause

serious personal injury, death or major

property damage.
Warns of hazards that CAN cause per-

sonal injury or property damage.

NOTICE: INDICATES SPECIAL INSTRUCTIONS

WHICH ARE VERY IMPORTANT AND

MUST BE FOLLOWED.

THOROUGHLY REVIEW ALL INSTRUCTIONS

AND WARNINGS PRIOR TO PERFORMING ANY

WORK ON THIS PUMP.
MAINTAIN ALL SAFETY DECALS.

UNIT NOT DESIGNED FOR USE

WITH HAZARDOUS LIQUIDS

OR FLAMMABLE GASES. THESE

FLUIDS MAY BE PRESENT IN

CONTAINMENT AREAS.

NOTICE: INSPECT UNIT FOR DAMAGE AND

REPORT ALL DAMAGE TO THE CARRIER

OR DEALER IMMEDIATELY.

1. Important Instructions

1. Inspect unit for damage. Report damage to carrier

immediately.

2. Electrical supply must be a separate branch circuit

with fuses or circuit breakers, wire sizes, etc., per

National and Local electrical codes. Install an all-leg

disconnect switch near pump.

ALWAYS DISCONNECT

ELECTRICAL POWER WHEN

HANDLING PUMP OR CONTROLS.

DANGER

WARNING

CAUTION

3. Motors must be wired for proper voltage (check

nameplate). Wire size must limit maximum voltage

drop to 10% of nameplate voltage at motor terminals,

or motor life and pump performance will be lowered.

4. Single-Phase: Thermal protection for single-phase units

is sometimes built-in (Check nameplate). If no built-in

protection is provided, use a contactor with proper

overload. Fusing is permissible if properly fused.

5. Three-Phase: Provide three-leg protection with proper

size magnetic starter and thermal overloads.

6. Maximum Liquid Temperatures:

212ºF (100ºC) with standard seal.

250ºF (120ºC) with optional high-temperature seal.
7. Maximum allowable operating pressure: 230 PSI

(15 bars).

8. Maximum number of starts per hour: 20, evenly

distributed.

9. Regular Inspection and Maintenance will increase

service life. Base schedule on operating time.

2. Installation

1. Close-coupled units may be installed inclined or vertical.

DO NOT INSTALL WITH MOTOR

BELOW PUMP. CONDENSATION

WILL BUILD UP IN MOTOR.

2. Locate pump as near liquid source as possible (below

level of liquid for automatic operation).

3. Protect from freezing or floods.
4. Allow adequate space for servicing and ventilation.
5. For close-coupled pumps, the foundation must be flat

and substantial to eliminate strain when tightening

bolts. Use rubber mounts to minimize noise and

vibration. Tighten motor hold-down bolts before

connecting piping to pump.

6. For frame-mounted pumps, permanent and solid

foundation is required for smooth operation. Bedplate

must be grouted to a foundation with solid footing.

7. Place unit in position on wedges located at four points

(Two below approximate center of driver and two

below approximate center of pump). Adjust wedges to

level unit, bringing coupling halves into reasonable

alignment. Level or plumb suction and discharge

flanges.

8. Make sure bedplate is not distorted and final coupling

alignment can be made within the limits of movement

of motor and by shimming if necessary.

9. Tighten foundation bolts finger tight and build dam

around foundation. Pour grout under bedplate making

sure the areas under pump and motor feet are filled

solid. Allow grout to harden 48 hours before further

tightening foundation bolts.

10. All piping must be supported independently of the

pump, and must “line-up” naturally. Never draw

piping into place by forcing the pump suction and

discharge connections!

11. Angular alignment of the flanges can best be accom-

plished using calipers at bolt locations (See illustra-

tion).

WARNING

Hazardous voltage

can shock, burn or

cause death.

CAUTION

WARNING

Hazardous fluids

can cause fire,

burns or death.