4. Refit the oil plug and tighten.

Tightening torque: 10-40 Nm (7.5-29.5 ft-lbs)

Service the pump

Type of service

Purpose

Inspection interval

Initial inspection

To make a check up of the pump

condition by a Xylem authorized

service representative and, based

on the result and findings from

these measures, to determine the

intervals for periodical inspection

and major overhaul for the specific

installation.

Within the first year of operation.

Periodical inspection

To prevent operational interruptions

and machine breakdown. Measures

to secure performance and pump

efficiency are defined and decided

for each individual application. It

can include such things as impeller

trimming, wear part control and

replacement, control of zinc-anodes

and control of the stator.

Up to every year. Applies to normal

applications and operating

conditions at media (liquid)

temperatures <40°C.

Major overhaul

To secure a long operating lifetime

for the product. It includes

replacement of key components

and the measures taken during an

inspection.

Up to every 3 years. This interval

apply to normal applications and

operating conditions at media

(liquid) temperatures <40°C.