Service the pump, Inspection – Xylem GK GV (8203, 8203X) User Manual
Page 38
WS001762A
4. Refit the oil plug and tighten.
Tightening torque: 10-40 Nm (7.5-29.5 ft-lbs)
Service the pump
Type of service
Purpose
Inspection interval
Initial inspection
To make a check up of the pump
condition by a Xylem authorized
service representative and, based
on the result and findings from
these measures, to determine the
intervals for periodical inspection
and major overhaul for the specific
installation.
Within the first year of operation.
Periodical inspection
To prevent operational interruptions
and machine breakdown. Measures
to secure performance and pump
efficiency are defined and decided
for each individual application. It
can include such things as impeller
trimming, wear part control and
replacement, control of zinc-anodes
and control of the stator.
Up to every year. Applies to normal
applications and operating
conditions at media (liquid)
temperatures <40°C.
Major overhaul
To secure a long operating lifetime
for the product. It includes
replacement of key components
and the measures taken during an
inspection.
Up to every 3 years. This interval
apply to normal applications and
operating conditions at media
(liquid) temperatures <40°C.
NOTICE:
Shorter intervals may be required when the operating conditions are extreme, for example
with very abrasive or corrosive applications or when the liquid temperatures exceed 40°C
(104°F).
Inspection
Maintenance
36