beautypg.com

Xylem IM132 R02 RSPA (FSPA) & RJSP Self-Priming Centrifugal Pumps User Manual

Page 7

background image

7

Maintenance – RSPA

LUBRICATION:
1. The pump requires no lubrication.
2. For the electric motor, refer to instructions provided by

the motor manufacturer.

SEAL REMOVAL:
1. Disconnect electrical service to pump.
2. Relieve system pressure by opening a faucet or drain

valve until water stops flowing.

3. Disconnect pressure switch tubing at the barbed fitting

on the pump case. If tubing does not slide off barbed

fitting easily, cut it as close to the fitting as possible.

4. Remove four cap screws which hold down the pump

seal plate and motor to the pump case. Piping need not

be disturbed.

5. Remove the pumping assembly, as one piece, (motor,

seal plate, diffuser and impeller) by carefully prying

them apart from the pump case. Exercise care as not to

damage impeller.

6. Remove the diffuser from the seal plate, exposing

the impeller.

7. Insert regular slotted screwdriver into the slot in the

motor shaft.

8. While holding the motor shaft with the screwdriver,

unscrew the impeller by turning counterclockwise.

9. Slide rotating part of seal assembly from shaft (as

shown in Figure 3). Separate seal plate from motor.

10. Remove stationary part of seal assembly (including

rubber seal boot) from seal plate.

Maintenance – RSPA

FIGURE 3

CERAMIC SEAL

ROTATING SEAL

CASE BOLT

MOTOR SHAFT

SEAL PLATE

O-RING

SEAL BOOT

IMPELLER

DIFFUSER

O-RING

NEW SEAL INSTALLATION:
1. Clean polished surface of stationary seal with a clean

cloth.
2. Wet the outer edge of the rubber seal boot with a

soapy solution.

3. Insert rubber seal boot and ceramic seal (polished side

exposed) into seal plate. Make a cardboard washer to

cover the ceramic seal surface to be used while pressing

seal into position. Cardboard washer is used to avoid

scratching ceramic surface. Discard cardboard washer

after ceramic seal installation.

4. Reposition seal plate onto motor and slide rotating seal

assembly onto motor shaft with carbon sealing face first

until rubber end ring slides over shaft shoulder.

5. Screw impeller clockwise onto motor shaft using

screwdriver in shaft end slot to hold the shaft.

6. Reattach diffuser to seal plate and carefully reposition

the pumping assembly to the pump case. Attach with

the four cap screws through motor bracket to case.

7. Connect the pressure tubing by pressing on to barb

fitting on pump case until tubing shoulders against stop

edge of fitting. If tubing was cut off, carefully remove

excess tubing from barb fitting with a knife, taking care

not to scratch the fitting.

MOTOR REMOVAL:
1. Follow Steps 1 - 10 of “Seal Removal” in this section.
MOTOR REPLACEMENT:
1. Follow Steps 1 - 7 of “New Seal Installation” in

this section.