Xylem IM116 R04 4 Submersible Pumps User Manual
Page 36
36
GENERACIÓN II - DE 2-HILOS, 4 PULG. DATOS
ELÉCTRICOS LA MONOFÁSICO, 60 HERTZ, 3450 RPM
GENERACIÓN II - DE 3-HILOS, 4 PULG. DATOS
ELÉCTRICOS LA MONOFÁSICO, 60 HERTZ, 3450 RPM
Carga plena Factor de servicio Amperaje
del rotor
bloqueado
Winding
Resis-
tance
Có-
digo
kVA
Tipo CP No. de
orden
HP
kW Voltios SF Amps Watts Amps Watts
PSC
de
2-
hilos
M05421
0.5 0.37 115 1.6
7.9
910
9.8
1120
28
1.4-2.0
H
M05422
0.5 0.37 230 1.6
4.0
845
4.7
1050
16
6.1-7.2
J
M07422
0.75 0.55 230 1.5
5.0
1130
6.2
1400
18
5.9-6.9
F
M10422
1.0 0.75 230 1.4
6.7
1500
8.1
1800
24
4.2-5.2
F
M15422
1.5
1.1
230 1.3
9.0
2000
10.4
2350
43
1.8-2.4
H
Carga plena Factor de servicio Ampe-
raje del
rotor blo-
queado
Winding
Resistance
Caja de
control
requerida
1
Tipo CP No.
de orden HP kW Voltios SF
Amps Watts Amps Watts
Prin-
ciple
(B-Y)
Ar-
ranque
(R-Y)
3-hilos
con
Q.D.
rectán-
gulo
del
co-
mienzo
del con-
densa-
dor
M05411 0.5 0.37 115 1.6
Y – 8.8
B – 8.8
R – 0
675
Y – 10.9
B – 10.9
R – 0
980
44
1.0-
1.4
2.5-
3.1
CB05411
M05412 0.5 0.37
230
1.6
Y – 5.3
B – 5.3
R – 0
740
Y – 6.1
B – 6.1
R – 0
1050
21
5.1-
6.1
12.4-
13.7
CB05412
M07412 0.75 0.55
1.5
Y – 6.6
B – 6.6
R – 0
970
Y – 7.8
B – 7.8
R – 0
1350
32
2.6-
3.3
10.4-
11.7
CB07412
M10412 1.0 0.75
1.4
Y – 8.1
B – 8.1
R – 0
1215
Y – 9.4
B – 9.4
R – 0
1620
41
2.0-
2.6
9.3-
10.4
CB10412
3-hilos
con
CSCR
(CR)
o el
rectán-
gulo de
control
magné-
tico del
contac-
tor
(MC)
M05412 0.5 0.37
1.6
Y – 4.2
B – 4.1
R – 1.8
715
Y – 4.8
B – 4.3
R – 1.8
960
21
1.0-
1.4
2.5-
3.1
CB05412CR
M07412 0.75 0.55
1.5
Y – 4.8
B – 4.4
R – 2.5
940
Y – 6.0
B – 4.9
R – 2.3
1270
32
5.1-
6.1
12.4-
13.7 CB07412CR
M10412 1.0 0.75
1.4
Y – 6.1
B – 5.2
R – 2.7
1165
Y – 7.3
B – 5.8
R – 2.6
1540
41
2.6-
3.3
10.4-
11.7 CB10412CR
M15412 1.5 1.1
1.3
Y – 9.1
B – 8.2
R – 1.2
1660
Y – 10.9
B – 9.4
R – 1.1
2130
49
2.0-
2.6
9.3-
10.4
CB15412CR o
CB15412MC
M20412 2
1.5
1.25
Y – 9.9
B – 9.1
R – 2.6
2170
Y – 12.2
B – 11.7
R – 2.6
2660
49
1.6-
2.2
10.8-
12.0
CB20412CR o
CB20412MC
M30412 3
2.2
1.15
Y – 14.3
B – 12.0
R – 5.7
3170
Y – 16.5
B – 13.9
R – 5.6
3620
76
1.1-
1.4
2.0-
2.5
CB30412CR o
CB30412MC
M50412 5
3.7
1.15
Y – 24.0
B – 19.1
R – 10.2
5300
Y – 27.0
B – 22.0
R – 10.0
6030
101
.62-
.76
1.36-
1.66
CB50412CR o
CB50412MC
¹ Un rectángulo de control de CSCR con un sufijo del CR se puede substituir por una conclusión magnética del modelo del contactor en MC.