Problem

Possible cause

Solution

Products prevent that wa-
ter flows into the water
collector.

Make sure that products
do not touch the rear
plate.

Water flows on the
ground.

The melting water outlet
does not flow in the evap-
orative tray above the
compressor.

Attach the melting water
outlet to the evaporative
tray.

The temperature in
the appliance is too
low.

The temperature regula-
tor is not set correctly.

Set a higher temperature.

The temperature in
the appliance is too
high.

The temperature regula-
tor is not set correctly.

Set a lower temperature.

6.1 Replacing the lamp

1

2

1.

Switch off the appliance.

2.

Press on the rear hook and at the
same time slide the cover in the di-
rection of the arrow.

3.

Replace the lamp with one of the
same power and specifically de-
signed for household appliances.
(the maximum power is shown on
the lamp cover).

4.

Slide the lamp cover into its original
position.

5.

Switch on the appliance.

6.

Open the door. Make sure that the
light comes on.

6.2 Closing the door

1.

Clean the door gaskets.

2.

If necessary, adjust the door. Refer
to "Installation".

3.

If necessary, replace the defective
door gaskets. Contact the Service
Center.

7. INSTALLATION

7.1 Positioning

WARNING!
If you are discarding an old appli-
ance that has a lock or catch on
the door, you must ensure that it
is made unusable to prevent
young children being trapped in-
side.

The appliance shall have the
plug accessible after installation.

Install this appliance at a location where
the ambient temperature corresponds to
the climate class indicated on the rating
plate of the appliance:

24 www.aeg.com