beautypg.com

Installation, 1 built-in appliances, 2 connection cable – AEG HK854320IB User Manual

Page 32: 3 to attach the seal to the rabbet, 4 assembly

background image

If you tried the above solutions and can-
not repair the problem, speak to your
dealer or the customer service. Give the
data from the rating plate, three digit
letter code for the glass ceramic (it is in
the corner of the glass surface) and an
error message that comes on.

Make sure, you operated the appliance
correctly. If not the servicing by a cus-
tomer service technician or dealer will
not be free of charge, also during the
warranty period. The instructions about
the customer service and conditions of
guarantee are in the guarantee booklet.

8. INSTALLATION

WARNING!
Refer to the Safety chapters.

Before the installation

Before the installation of the appliance,
record the information below from the
rating plate. The rating plate is on the
bottom of the appliance casing.
• Model ...........................
• PNC .............................
• Serial number ....................

8.1 Built-in appliances

• Only use the built-in appliances after

you assemble the appliance into cor-
rect built-in units and work surfaces
that align to the standards.

8.2 Connection cable

• The appliance is supplied with the

connection cable.

• Replace the damaged mains cable

with a special cable (type H05BB-F
Tmax 90°C; or higher). Speak to your
local Service Centre.

8.3 To attach the seal to the
rabbet

• Clean the rabbet in the work surface.
• Bond the seal stripe supplied on the

upper surface of the rabbet along the
edges of the cut out section.

• Cut the seal stripe into four pieces in

relation to the length of the edges of
the rabbet.

• For the four corners of the rabbet the

ends of the seal stripes must be cut in-
to mitres. Do not bond the ends over
one another.

• Bond the seal stripe flush into the cor-

ner of the rabbet. Make sure that no
silicon compound can get below the
glass ceramic when grouting.

• Do not extend the tapes.

8.4 Assembly

min.

50mm

min.

500mm

min.

2mm

32 www.aeg.com