beautypg.com

Ir illuminator installation, Battery installation, Ir illuminator operation – Armasight IAIR850IR000001 IR850 Detachable Long Range Infrared Illuminator User Manual

Page 2: Delivery set

background image

IR IllUMINATOR INSTAllATION

The IR810/IR850/IR940/IR810W/IR850W are the removable devices that can be installed on the rail of

night vision device (NVD). To install the IR illuminator on your NVD, perform the following steps:
1) Install the Picatinny adapter on the rail of your NVD (if Picatinny rail not installed on your NVD).
2) Loosen the fixing screw on the IR illuminator mount.
3) Place the IR illuminator on the Picatinny rail.
4) Tighten the fixing screw.

BATTERY INSTAllATION

CAUTION:

Ensure that the IR illuminator is off before installing the battery.

The Armasight IR illuminators runs on one CR123A battery. Install the battery as follows:
1) Unscrew the battery cap.
2) Install the battery into the battery compartment. Align the plus sign on the battery with the plus
sign on the cap face.
3) Replace the battery cap.

IR IllUMINATOR OPERATION

CAUTION:

Device is equipped with an infrared LED which is nit hazardous to human health. However do not

point the IR illuminator at eyes.

To switch the IR ON, rotate the operation switch from the OFF position.
The power of the beam emitted by the IR illuminator can be changed. To change the brightness of

the beam, rotate the illuminator operation switch. The positions of brightness levels are marked on

the back side of cap with dots of a different size, respectively to four different radiation output power

levels.
You can change the field of coverage by adjusting the IR beam.

To focus the beam, rotate the IR illuminator lens until the de-

sired field of coverage is reached.
Adjust the IR spot position in the field of view of the NVD as

follows:
1) Loosen the screw of the clamp on the IR illuminator mount.
2) Turn on the sight and the IR illuminator.
3) Carefully move the lens of the IR810/IR850 up and down and

side to side. While looking through the eyepieces of your de-

vice, observe the IR spot position.
4) Once the IR spot is centered in the field of view, tighten the

fixing screw of the clamp.

dElIVERY SET

IR illuminator, CR123A Lithium battery, User’s manual, Allen keys, Bracket*, Picatinny Mount Adapter*.

* Optional equipment or equipment with variants.

focus adjustment

fixing screw

battery cap

operation switch

screw of clamp

beam direction

adjustment

picatinny adapter

Armasight Inc.

815 Dubuque Avenue, South San Francisco, CA 94080

[email protected], www.armasight.com

Phone: (888)959-2259

Fax: (888)959-2260

Intl Phone/Fax: (650)492-7755