beautypg.com

8 rebuilding the raid, Rebuilding the raid with other non-raid disk – Asus P5BV-C User Manual

Page 111

background image

ASUS P5BV-C Series

5-15

5.3.8

Rebuilding the RAID

This option is only for the RAID 1, RAID 5 and RAID 10 sets.

Rebuilding the RAID with other non-RAID disk

If any of the SATA hard disk drives included in the RAID array failed, the system

displays the status of the RAID volume as “Degraded” during POST. You can rebuild

the RAID array with other installed non-RAID disks.
To rebuild the RAID with other non-RAID disk:
1. At the prompt, press + to enter the Intel Matrix Storage Manager

RAID configuration.

2. If there is a non-RAID SATA Hard Disk available, the utility will prompt to rebuild

the RAID. Press , then use up/down arrow keys to select the destination

disk or press to exit.

Select a destination disk with the same size as the original hard disk.

3. The utilty immediately starts rebuilding after the disk is selected. The status of

the degraded RAID volume is changed to “Rebuild”.

DEGRADED VOLUME DETECTED

“Degraded“ volume and disk available for rebuilding detected.

Selecting a disk initiates a rebuild. Rebuild completes in the

operating system.

Select the port of destination disk for rebuilding (ESC to exit):

Port Drive Model

Serial#

Size

3HDS722580VLSA80

VN6Bxxxx

76.7GB

[ ]- Previous/Next [Enter]- Selects [ESC]- Exit

This manual is related to the following products: