Procom LPZ-1900 User Manual
Lpz 1900
LPZ 1900
Coaxial Low-Pass Filter for the 1900 MHz Band
DESCRIPTION
Passes all signals in or below the 1400 - 1900 MHz band.
Rejects signals above this range.
Absolute stop band from 3.8 GHz to 12.4 GHz.
– no degradation at harmonics (Zolotarev-characteristic).
Attenuation in stop band better than 60 dB.
Insertion loss in pass range less than 0.4 dB.
Provided with brackets for panel mounting.
ORDERING DESIGNATIONS
TYPE
PRODUCT NO.
LPZ 1900
200001293
SPECIFICATIONS
ELECTRICAL
MODEL
LPZ 1900
APPLICATION
Low-pass filter for the 1900 MHz band
FREQUENCY
Pass band: 1400 - 1900 MHz
Stop band: 3.8 - 12.4 GHz
MAX. INPUT POWER
150 W
INSERTION LOSS (PASS BAND)
≤ 0.4 dB
1 dB CUT-OFF FREQUENCY
> 1950 MHz
ATTENUATION (STOP BAND)
> 60 dB
MECHANICAL
TEMP. RANGE
–30° C → +80° C
CONNECTORS
N-female
DIMENSIONS (L x W x H)
95 x 40 x 36 mm
WEIGHT
Approx. 80 g
TYPICAL RESPONSE CURVES
The LPZ 1900 is used to prevent RFI (Radio Frequency Interference) caused
by excessive harmonic generation from transmitters operating in the 1900
MHz band. By rejection, the filter reduces the amplitude of the harmonics
and prevents them from being radiated by the antenna.
The filter is normally used in connection with base station transmitters, but
as it is mechanically very ruggedly designed, it is perfectly suited for mobile
and marine applications as well.
PROCOM A/S reserve the right to amend specifications
without prior notice.
22/08/13