Procom LPz-175 User Manual
Lpz 175

LPZ 175
Coaxial Low-Pass Filter for the 160 MHz Band
DESCRIPTION
Passes all signals in or below the 160 MHz-band.
Rejects signals above this range.
Absolute stop band from 310 MHz to 6 GHz
– no degradation at harmonics (Zolotarev-characteristic).
Attenuation in stop band better than 60 dB.
Insertion loss in pass range less than 0.4 dB.
Provided with brackets for panel mounting.
ORDERING DESIGNATIONS
TYPE
PRODUCT NO.
LPZ 175
210001324
SPECIFICATIONS
ELECTRICAL
MODEL
LPZ 175
APPLICATION
Low-pass filter for the 160 MHz band
FREQUENCY
Pass band: 135 – 175 MHz
Stop band: 310 MHz - 6 GHz
MAX. INPUT POWER
150 W
INSERTION LOSS (PASS BAND)
≤ 0.4 dB
1 dB CUT-OFF FREQUENCY
> 180 MHz
ATTENUATION (STOP BAND)
> 60 dB
MECHANICAL
TEMP. RANGE
–30° C → +80° C
CONNECTORS
N-female
DIMENSIONS (L x W x H)
435 x 40 x 36 mm
WEIGHT
Approx. 530 g
TYPICAL RESPONSE CURVES
PLEASE NOTE
The LPZ 175 is used to prevent RFI (Radio Frequency Interference) caused
by excessive harmonic-generation from transmitters operating in the 160
MHz band. By rejection, the filter reduces the amplitude of the harmonics
and prevents them from being radiated by the antenna.
The filter is normally used in connection with base station transmitters, but
as it is mechanically very ruggedly designed, it is perfectly suited for mobile
and marine applications as well.
PROCOM A/S reserve the right to amend specifications
without prior notice.
25/09/13