Procom PRO-phy450-2 User Manual
Pro-phy450-2
PRO-PHY450-2
2-Channel Hybrid Ring Combiner for 450 MHz Transmitters
DESCRIPTION
Combining two transmitters or receivers on the same antenna.
Better utilization of good antenna position.
Two antennas on the same transmitter or receiver.
Combining two signal generators.
The only combining option with very small TX-TX frequency spacing.
60 W load supplied (other loads or no load as option).
ORDERING DESIGNATIONS
TYPE
PRODUCT NO.
FREQ. RANGE
PRO-PHY450-2-TETRA
210001126
380 - 400 MHz
PRO-PHY450-2-1
210000580
400 - 420 MHz
PRO-PHY450-2-2
210000546
415 - 435 MHz
PRO-PHY450-2-3
210000579
430 - 450 MHz
PRO-PHY450-2-4
210000542
445 - 465 MHz
PRO-PHY450-2-5
210000570
460 - 480 MHz
SPECIFICATIONS
ELECTRICAL
FILTER TYPE
Hybrid Ring Junction
FREQUENCY
380 - 475 MHz (see table)
MAX. INPUT POWER
50 W per channel
(max. 150 W with larger load)
INSERTION LOSS
< 3.4 dB @ 10 MHz BW
< 3.7 dB @ 20 MHz BW
ISOLATION TX
1
-TX
2
(*see note)
> 35 dB @ 10 MHz BW
> 30 dB @ 20 MHz BW
IMPEDANCE
Nom. 50 Ω
LOAD (**see note)
60 W load fitted (other ratings available)
SWR
< 1.5 with all other ports terminated
with 50 Ω
MECHANICAL
TEMP. RANGE
–30° C → +60° C
CONNECTORS
N-female (other types as option)
DIMENSIONS (L x W x H)
216 x 89 (incl. conn.) x 42 mm (excl. load)
WEIGHT
Approx. 700 g (excl. load)
*The isolation between the TX ports is directly dependent on the terminating
SWR on the antenna port. With an antenna load SWR = 1.5, the isolation
between the two TX ports will be reduced to 20 dB @ 5 MHz bandwidth.
**The SWR of the loads should be < 1.1! The load should be able to
dissipate 1/2 of the total input power.
E.g.: With 50 W input in total for the two channels, the load should be able
to dissipate 50 W x 1/2 = 25 W.
TYPICAL RESPONSE CURVE
PROCOM A/S reserve the right to amend specifications
without prior notice.
11/12/12