beautypg.com

Procom PRO-phy450-2 User Manual

Pro-phy450-2

background image

PRO-PHY450-2

2-Channel Hybrid Ring Combiner for 450 MHz Transmitters

DESCRIPTION

Combining two transmitters or receivers on the same antenna.
Better utilization of good antenna position.
Two antennas on the same transmitter or receiver.
Combining two signal generators.
The only combining option with very small TX-TX frequency spacing.
60 W load supplied (other loads or no load as option).

ORDERING DESIGNATIONS

TYPE

PRODUCT NO.

FREQ. RANGE

PRO-PHY450-2-TETRA

210001126

380 - 400 MHz

PRO-PHY450-2-1

210000580

400 - 420 MHz

PRO-PHY450-2-2

210000546

415 - 435 MHz

PRO-PHY450-2-3

210000579

430 - 450 MHz

PRO-PHY450-2-4

210000542

445 - 465 MHz

PRO-PHY450-2-5

210000570

460 - 480 MHz

SPECIFICATIONS

ELECTRICAL

FILTER TYPE

Hybrid Ring Junction

FREQUENCY

380 - 475 MHz (see table)

MAX. INPUT POWER

50 W per channel

(max. 150 W with larger load)

INSERTION LOSS

< 3.4 dB @ 10 MHz BW

< 3.7 dB @ 20 MHz BW

ISOLATION TX

1

-TX

2

(*see note)

> 35 dB @ 10 MHz BW

> 30 dB @ 20 MHz BW

IMPEDANCE

Nom. 50 Ω

LOAD (**see note)

60 W load fitted (other ratings available)

SWR

< 1.5 with all other ports terminated

with 50 Ω

MECHANICAL

TEMP. RANGE

–30° C → +60° C

CONNECTORS

N-female (other types as option)

DIMENSIONS (L x W x H)

216 x 89 (incl. conn.) x 42 mm (excl. load)

WEIGHT

Approx. 700 g (excl. load)

*The isolation between the TX ports is directly dependent on the terminating

SWR on the antenna port. With an antenna load SWR = 1.5, the isolation

between the two TX ports will be reduced to 20 dB @ 5 MHz bandwidth.
**The SWR of the loads should be < 1.1! The load should be able to

dissipate 1/2 of the total input power.
E.g.: With 50 W input in total for the two channels, the load should be able

to dissipate 50 W x 1/2 = 25 W.
TYPICAL RESPONSE CURVE

PROCOM A/S reserve the right to amend specifications

without prior notice.
11/12/12