Procom BPBR 900-...-125 User Manual
Bpbr 900
BPBR 900/...-125
Band-Pass/Band-Reject Filters for the 900 MHz Band
DESCRIPTION
High power base station band-pass/band-reject filters for the 800 – 960
MHz range.
The use of large ø125 mm cavities means a high Q, resulting
in a very narrow pass/reject spacing.
The large dimensions also mean a high power rating.
Unloaded Q of a single cavity is approx. 4500.
High frequency stability on temperature and power.
Mounted on 19" brackets.**
BPBR 900/1-125
BPBR 900/2-125
BPBR 900/3-125
ORDERING DESIGNATIONS
TYPE
PRODUCT NO.
BPBR 900/1-125
200001912
BPBR 900/2-125
200001913
BPBR 900/3-125
200001914
SPECIFICATIONS
ELECTRICAL
MODEL
BPBR
900/1-125
BPBR
900/2-125
BPBR
900/3-125
FREQ. RANGE
800 - 960 MHz
800 - 960 MHz
800 - 960 MHz
MAX. INPUT
POWER
300 W @
0.5 dB IL
125 W @
2.0 dB IL
300 W @
1.0 dB IL
125 W @
4.0 dB IL
300 W @
1.5 dB IL
125 W @
6.0 dB IL
INSERTION LOSS
Adjustable
0.3 - 2.0 dB
Adjustable
0.6 - 4.0 dB
Adjustable
0.9 - 6.0 dB
REJECT.
Depending on
spacing and
configuration.
1 MHz:
2 MHz:
3 MHz:
15 (< 0.5)
25 (< 0.5)
30 (< 0.8)
35 (< 1)
55 (< 1)
60 (< 1)
60 (< 1.5)
80 (< 1.5)
90 (< 1.8)
IMPEDANCE
Nom. 50 Ω
Nom. 50 Ω
Nom. 50 Ω
SWR
(at resonance)
< 1.5
< 1.5
< 1.5
MECHANICAL
TEMP. RANGE
RH 0-90%
non-condensing
–30° C →
+60° C
-30° C →
+60° C
–30° C →
+60° C
FREQ.
STABILITY
Approx. 1.5
ppm/° C
Approx. 1.5
ppm/° C
Approx. 1.5
ppm/° C
CONNECTORS
N-female
N-female
N-female
DIMENSIONS
ø125 x
150 mm
L:125 x W:250 x
H:150 mm
L:125 x W:375 x
H:150 mm
WEIGHT
Approx.
0.7 kg
Approx.
1.5 kg
Approx.
2.5 kg
PROCOM A/S reserve the right to amend specifications
without prior notice.
30/05/13