beautypg.com

Elevation view, Plan view – Aqua-Pure SS20 EPE-316L User Manual

Page 4

background image

D

E

G

C

A

B

HEIGHT REQUIRED TO
CHANGE CARTRIDGES

Elevation View

(See Plan View for True Orientation)

2

3

4

5

6

7

8

HAND KNOB

COVER

PRESSURE PLATE ASSEMBLY

COVER GASKET

V-BAND CLAMP

CARTRIDGE POSTS

DRAIN PLUG 3/4" NPT
(SLUDGE DRAIN)

CARTRIDGE
PEDESTALS

FLOW
BAFFLE

CENTER
ROD

1/4" NPT
VENT PLUG

DIRTY DRAIN
ABOVE CLEAN DRAIN
3/4" NPT

1

Plan View

T

E

L

T

U

O

T

E

L

N

I

8

9

T-BOLT
KIT

F

SS4-316L, SS8-316L, SS12-316L and SS20-316L Filter Housing Series

Installation

1)Installing the Filter Housing (SS4-316L, SS8-316L, SS12-316L and SS20-316L Filter Housing Series)

The fi lter housing should be placed on 8” (20 cm) cinder or cement blocks to permit ease of draining. Locate the inlet (marked as “IN” and
Outlet (marked as “OUT”) connections on the housing cylinder. Connect the water supply line piping to the Inlet connection and the fi ltered
water piping serving the building to the Outlet connection. Shut off valves are to be installed on each side of the housing (See note). DO
NOT
install the fi lter housing backwards by connecting the water supply line piping to the Outlet. The drain plugs should then be removed
and either a drain line assembly (with two valves) or two hose bibs (faucets) should be installed. See Figure 1 for proper installation. Install
fi lter cartridges per Step 2 prior to fi lter housing start-up.

Note: When the housing is installed in close proximity to the water metere or pressure tank, the main shut off valve may be used for the
Inlet water control valve.

Note: Installation must comply with state and local plumbing codes.

4