Aqua-Pure ASB1001 User Manual
Page 12
2-5
INSTALLER/USER DISPLAYS
SETTING DAYS BETWEEN REGENERATION
Step 1)
Begin in normal mode and press SET + ▲ for three seconds simultaneously.
Step 2)
Set the hours for regeneration using ▲ or ▼. Press SET and proceed to step 3.
Step 3)
Set the minutes for regeneration using ▲ or ▼. Press SET and proceed to step 4.
Step 4)
Set the days for regeneration between 1 and 99. Press SET to exit Installer/User Displays and Settings.
GENERAL OPERATION
When operating, the system will either display the current time of day or the days remaining until the next regeneration. Use ▲ or ▼ to toggle between the
two displays. If the remaining days is at 1, the system will regenerate at the preset time.
An arrow will appear pointing to REGEN when the system calls for regeneration.
REGENERATION MODE
When the system is regenerating, untreated water will be used. Therefore, systems are typically set to regenerate during times of low water usage—such as
when the household is asleep.
During regeneration, the arrow will point to REGEN and the display will change to Regeneration Cycle Display, indicating the time remaining. The system
automatically runs through the steps of regeneration; upon completion, treated water is ready for use.
HOW TO MANUALLY INITIATE REGENERATION
If a system needs to be regenerated before the next scheduled time, manual regeneration can be initiated. This may be necessary during times of heavy water
usage, including house guests or heavy laundry days.
To initiate a manual regeneration at the preset delay time, press ▲ and ▼ simultaneously. Release. An arrow will point to REGEN if regeneration is expected
“tonight.” To cancel, press ▲ and ▼ simultaneously. Release.
To initiate an immediate manual regeneration, press ▲ and ▼ simultaneously for three seconds. This request cannot be cancelled.
HOW TO SET TIME OF DAY
Step 1)
Press SET
Step 2)
Use ▲ and ▼ to adjust the current time hour. Time display will be 12 hour with PM indicator with
60 Hz line frequency detection on power-up. Time display will be 24 hour without the PM indica-
tor with 50 Hz line frequency on power-up. Press SET and proceed to step 3.
Step 3)
Use ▲ and ▼ to adjust the current time minutes. Press SET to exit Set Time of Day.
Power Loss
If power is lost for more than 8 hours, the current time of day will need to be reset. If the system is in the
middle of regeneration upon power loss, the control will continue regeneration at the point of interruption
when power is restored.
Error Message
Contact your Dealer/Installer or our Customer Service Department at 1-800-222-7880 for assistance if the dis-
play shows “E1,” “E2,” “E3” or “E4.” These messages are indications the valve did not function properly.
STEP 1
SET
STEP 2
SET
Regen
Min. Fill
Regen
Time
Time
PM
Days To
Regen
STEP 3
SET
Regen
Min. Fill
Regen
Time
Time
PM
Days To
Regen
SET
Regen
Min. Fill
Regen
Time
Time
PM
Days To
Regen