beautypg.com

Technical data, Replacing the lamp, Closing the door – AEG SKS58800F0 User Manual

Page 27

background image

Problem

Possible cause

Solution

The temperature in the

appliance is too high.

The temperature regulator is not

set correctly.

Set a lower temperature.

The door is not closed correctly.

Refer to "Closing the door".

The product temperature is too

high.

Let the product temperature de-

crease to room temperature be-

fore storage.

Many products are stored at the

same time.

Store less products at the same

time.

There is no cold air circulation in

the appliance.

Make sure that there is cold air

circulation in the appliance.

Replacing the lamp

1.

Disconnect the appliance.

2.

Push the movable part to unhook the

lamp cover (1).

3.

Remove the lamp cover (2).

4.

Replace the lamp with one of the same

power and specifically designed for do-

mestic appliances only.

5.

Install the lamp cover.

6.

Connect the appliance.

7.

Open the door. Make sure that the lamp comes on.

Closing the door

1.

Clean the door gaskets.

2.

If necessary, adjust the door. Refer to "Installation".

3.

If necessary, replace the defective door gaskets. Contact the Service Center.

TECHNICAL DATA

Dimension of the recess

Height

880 mm

Width

560 mm

Depth

550 mm

Voltage

230 V

Frequency

50 Hz

The technical information are situated in the rating plate on the internal left side of the

appliance and in the energy label.

1

2

Technical data

27