CAUTION: Maintenance
DISASSEMBLY
1. Replacement parts may be available at the store where you purchased
your faucet.
2. When replacement parts are not available, please write or call Price
Pfister Consumer Service.
3. Always turn off water and relieve pressure before working on your
faucet.
NOTE: Trim Care
Cleaning Instructions:
For all Handles and decorative finishes, use only a soft damp
cloth to clean and shine. Use of polish, detergents, abrasive
cleaners, organic solvents or acid may cause damage. Use of
other than a soft damp cloth will nullify our warranty!
Special Trim:
Trim products which contain Porcelain or other similar
substance are not acceptable for public areas or Commercial
use. Installation of Said Trim is at Users Risk!
1–800–PFAUCET (1–800–732–8238)
For Toll-Free Pfaucet information call
1–800–PFAUCET (1–800–732–8238)
or visit www.pricepfister.com
• Installation Support
• Care and Warranty Information
13 VALVE CARTRIDGE REMOVAL
Turn off water supplies and relieve pressure before working on your faucet!
Detach Decorative Button (13A) by pulling it out. Using a
3
/
32
” Hex wrench, loosen
Set Screw (13B) and remove Handle (13C). Remove the Dome Cap (13D) by unscrewing
counterclockwise. Using pliers, unscrew the retainer ring (13E). Carefully remove the
Cartridge (13F) by pulling it straight up and out. Reassemble valve by reversing steps.
MAINTENANCE & CARE
12 FLUSHING & AERATOR CLEANING
After installation is complete, remove Aerator Housing (12A). Turn Valves (12B) on
and allow both hot and cold water to run for at least one minute each. While water is
running, check for leaks. To clean the aerator, disassemble Aerator Housing (12A) by
separating the Aerator Shell (12C), Basket (12D), and Washer (12E). Once parts have
been cleaned, reassemble by reversing steps.
4
12D
12C
12A
12B
12E
5A
13A
13B
13C
13D
13E
13F