DRAIN BODY INSTALLATION

FAUCET FUNCTIONS

11

13

11 HOSE CONNECTION

From underneath sink, push the Center Connector (11A) onto receiving Tube (11B),
until unable to push any further. Pull down on the quick connect housing (11A). If the
housing and the Inner Collet (11C) separate slightly but do not pull off receiving Tube
(11B), the connection is secure.
Slide the End Connectors (11D) with arrow (11E) pointing up onto the Valve Bodies (11F).
Push the End Connectors (11D) all the way up until completely seated. Be careful not
to damage O-Rings (11G).

12 WATER SUPPLY CONNECTIONS

First, thread Inlet Connectors (12A) into Water Supply Lines (12B). Then, insert Inlet
Connectors (12A) into Valve Bodies (12C).

Hot water supply lines go into left inlet.

Cold water supply lines go into right inlet. (Supply lines not included). Please follow
manufacturer’s instructions when installing supply lines. Next, insert Clips (12D) into
Valve Body Holes (12E), to secure unit.

WARNING: Do not twist Inlet Connectors (12A) once installed!

13 POP-UP INSTALLATION

Install and adjust Pop-Up (13A) using separate instructions supplied with the Pop-Up
assembly.

14 UNIT START UP

Turn on hot and cold water supplies, and check for leaks above and below the sink.

15 FAUCET FUNCTION

COLD valve: close-counterclockwise, open-clockwise; HOT valve: close-clockwise,
open-counterclockwise.