Data sheet, Sv01-pl, Functional description – Procom SV01-PL User Manual
Page 2: Voltage supply module for nsa-pl, Block diagram sv01-pl
Date:
20.07.2011
Page: 2/3
Author:
VS
Document-No.:
DB_SV01-PL_2104
_
02_en
© 2011 ProCom, All rights and technical changes reserved.
Data Sheet
SV01-PL
Voltage supply module for NSA-PL
Block diagram SV01-PL
KS
48V DC
48V - 72V DC
+5V
GND
SV01-PL
-SV01
(-48V, -60V, -72V)
+SV01
(0V)
BUS
P
C
M
I/O
S
t
e
u
e
r
u
n
g
/
C
o
n
t
r
o
l
Al
On
Anzeige / Indication
-48V
The DVS-21 slide-in module SV01-PL is part of the ProCom SOS Line concept.
Whenever the 48V DC supply voltage for feeding the SOS line is not sufficient due to cable
length, the SV01-PL module is applied. It converts the nominal supply voltage of 48V DC of
the DVS-21 system into either 48V DC or 60V DC or 72V DC and forwards it towards a NSA-
PL module. At the same time, output and input voltage are isolated galvanically. Thus, it for-
wards a transformed supply voltage towards the WPS-PL call stations. Moreover, it provides
continuous short-circuit protection for the NSA-PL module connected.
The output voltage is set up in using the configuration software ICS.
For monitoring both output voltage and output current of the SV01-PL are measured and the
reading is passed to the processor module. There, as option, it can be evaluated. The vari-
ous operational statuses are displayed on the front plate LEDs.
Functional description: