Seite2, Dvs-21, Industrial application – Procom IP, ISDN, E1 Industrial Application User Manual
Page 2: Software functionality, Performance characteristics, Technical data
All rights and changes reserved V1.2
Software Functionality
!
Menu-guided programming in Windows operating system
!
Saving of the functions and the call connection plan in the software
!
Remote configuration or diagnosis and maintenance over modem interfaces
!
Special alarm procedures programmable
Performance Characteristics
!
Freely configurable functions under a menu-guided configuration programme in
Windows
!
Storage of 4 configuration files (databanks) and operating system states
!
Data storage on flash memory
!
Remote programming, diagnosis and maintenance via modem interface
!
Transmission of switching and signalling functions (remote control/remote
monitoring)
!
Time to establish connection: < 200 ms
!
Max. 100 configurable priority levels
!
Call storage configurable up to 60 sec.
!
Group/all calls: 16 per call station
!
Permanent monitoring of the system modules
!
Group malfunction signal with floating output
!
Functions compliant with acoustic standards DIN EN/IEC or VDE
!
Loudspeaker circuit monitoring and acknowledge signals
!
Analogue radio switching over a/b and lines
!
Keys with maintained contact, configurable as needed
!
Explosion-protected call stations
-
-
- Up to 100
- LCPU e
Technical Data
!
Modules with 19” slide-in technology 3 HE + 1 HE (inscription strip)
!
Modular construction for up to 600 call stations and 20 kW
!
Bus structure
!
48 lines of communication
!
Digital amplifier with disaster switching
!
Operating voltage range: 48 V DC (-10%) to 60 V DC (+15%)
!
Climate class 3K4 according to DIN EN 60721-3-3/IEC 721-3-3 (+5 ° to +40 °C; 5 to
95% relative humidity)
!
Integrated clock with automatic summer/winter changeover
!
Up to 104 call stations can be switched in per system:
Wire saving technology over symmetric 2 or 4-wire,
for voice frequency and for data
Line switch-off, a/b for low frequency and lines
!
A maximum of 17 digital 100 W amplifiers can be switched in per system
!
Digital voice storage:
channels
quipped with up to 2 GB Compact Flash
or DSS1 with 4 MB flash memory chip
Software Functionality
Performance Characteristics
Technical Data
!
Menu-guided programming in Windows operating system
!
Saving of the functions and the call connection plan in the software
!
Remote configuration or diagnosis and maintenance over modem interfaces
!
Special alarm procedures programmable
!
Freely configurable functions under a menu-guided configuration programme in
Windows
!
Storage of 4 configuration files (databanks) and operating system states
!
Data storage on flash memory
!
Remote programming, diagnosis and maintenance via modem interface
!
Transmission of switching and signalling functions (remote control/remote
monitoring)
!
Time to establish connection: < 200 ms
!
Max. 100 configurable priority levels
!
Call storage configurable up to 60 sec.
!
Group/all calls: 16 per call station
!
Permanent monitoring of the system modules
!
Group malfunction signal with floating output
!
Functions compliant with acoustic standards DIN EN/IEC or VDE
!
Loudspeaker circuit monitoring and acknowledge signals
!
Analogue radio switching over a/b and lines
!
Keys with maintained contact, configurable as needed
!
Explosion-protected call stations
!
Modules with 19” slide-in technology 3 HE + 1 HE (inscription strip)
!
Modular construction for up to 600 call stations and 20 kW
!
Bus structure
!
48 lines of communication
!
Digital amplifier with disaster switching
!
Operating voltage range: 48 V DC (-10%) to 60 V DC (+15%)
!
Climate class 3K4 according to DIN EN 60721-3-3/IEC 721-3-3 (+5 ° to +40 °C; 5 to
95% relative humidity)
!
Integrated clock with automatic summer/winter changeover
!
Up to 104 call stations can be switched in per system:
- Wire saving technology over symmetric 2 or 4-wire,
for voice frequency and for data
- Line switch-off, a/b for low frequency and lines
!
A maximum of 17 digital 100 W amplifiers can be switched in per system
!
Digital voice storage:
- Up to 100 channels
- LCPU equipped with up to 2 GB Compact Flash
or DSS1 with 4 MB flash memory chip
DVS-21
Industrial Application
Hazard Alert System in compliance
with DIN VDE 0833-4
IP, ISDN, E1, 2 wire connection possible
International sales by:
ProCom
Professional Communication
& Service GmbH
Alfredstrasse 157
D-45131 Essen
www.procom-communication.de
Tel.:
+49 (0) 201 860 670 - 90
Fax.: +49 (0) 201 860 670 - 98
[email protected]
Deutschland / Germany
National sales by:
RSR Datacom GmbH & Co. KG
Alfredstrasse 157
D-45131 Essen
www.rsr-datacom.de
Tel.:
+49 (0) 201 860 670 - 0
Fax.: +49 (0) 201 860 670 - 40
[email protected]
A system that
speaks for itself.