1 installation procedures, P.i.p, Pip2 – Crown Audio P.I.P.-FTE User Manual
Page 6: P.i.p.–fte page 6, Fig. 3.2 subsonic/ bass filter settings, Mod- ule or panel (two screws). for, Amplifiers, this may in- volve disconnecting the, Input adapter (see figures 3.4 and 3.5). if a
P.I.P.–FTE
Page 6
10
100
1 K
FREQUENCY (Hz)
dB
0
–6
–12
–18
FLAT
50 Hz
100 Hz
300 Hz
Fig. 3.2 Subsonic/
Bass Filter Settings
3.1 Installation Procedures
You may need a phillips screw-
driver to remove the existing
P.I.P.
module or panel from your ampli-
fier.
CAUTION:
Before connecting
this or any
P.I.P.
to your amplifier,
it is important to turn its level
controls down, turn it off and re-
move the AC power. Don’t touch
the circuitry. Even though the
amplifier is off, there could still be
enough energy remaining to
cause electric shock.
1. Turn down the level controls
(full counterclockwise), turn off
the amplifier and unplug it from
the AC power source.
2. Remove the existing
P.I.P.
mod-
ule or panel (two screws). For
PIP2
amplifiers, this may in-
volve disconnecting the
P.I.P.
from a
PIP2
input adapter (see
Figures 3.4 and 3.5). If a
PIP2
A
B
B
A
18 PIN (B)
20 PIN (A)
Q43528-1
FROM AMPLIFIER
P.I.P.
MODULE
BACK PANEL
OF PIP2
AMPLIFIER
PIP2 CONNECTOR
BOARD
Fig.3.4 PIP2 Input Adapter
Connection
Fig. 3.5 Installation into a
PIP2 Amplifier
P.I.P.
MODULE
BACK PANEL
OF AMPLIFIER
Fig. 3.3 Installation into a
Standard P.I.P. Amplifier