Factory Direct Hardware Hansgrohe 11020 User Manual
Page 10

10
English
Set the High Temperature Limit
Stop (optional)
Lift the handle (1).
Use a 4 mm Allen wrench to push the screw cover
into the handle (2).
Use the 4mm Allen wrench to loosen the handle
screw 4 complete revolutions (3).
Remove the handle (4).
Remove the flange.
Remove the handle screw (1).
Remove the high temperature limit stop (2).
Replace the high temperature limit stop so that the pin
on the cartridge is in the desired slot on the limit stop.
Note: the temperatures given in the diagram as-
sume a water heater temperature of 140° F, a cold
water temperature of 50°F and a water pressure of
45 PSI.
Replace the flange (1).
Replace the handle screw. Use the Allen wrench to
turn the screw 4 revolutions (2).
Replace the handle (1). Tighten the handle screw (2).
Install the screw cover (3).