Set the High Temperature Limit
Stop (optional)
Lift the handle (1).
Use a 4 mm Allen wrench to push the screw cover 
into the handle (2). 
Use the 4mm Allen wrench to loosen the handle 
screw 4 complete revolutions (3). 
Remove the handle (4).
Remove the flange.
Remove the handle screw (1).
Remove the high temperature limit stop (2).
Replace the high temperature limit stop so that the pin 
on the cartridge is in the desired slot on the limit stop. 
Note: the temperatures given in the diagram as-
sume a water heater temperature of 140° F, a cold 
water temperature of 50°F and a water pressure of 
45 PSI. 
Replace the flange (1).
Replace the handle screw. Use the Allen wrench to 
turn the screw 4 revolutions (2).
Replace the handle (1). Tighten the handle screw (2).
Install the screw cover (3).