beautypg.com

Dexter Laundry T-400 (On-Premise) User Manual

Page 6

background image

INJECTION SOURCE DETAILS

The washer control may be programmed to send 120V output signals for a chemical injection
system. The signals are not intended as a power source and must be limited to less than 100
milliamps of current. There is a separate terminal block for connection of the external injection
signals. For the injection sources, program codes 0 through 6 are as shown in the table below.

Dexter

Recommended

Connections

Controller

Programmed

Signals

Injection

Terminal Block

Circuits

Detergent

1

A

Bleach

2

B

Starch

3

C

Sour/Softener

4

D

5

A and B

6

C and D

0

None



CHECKOUT

After all mounting, plumbing and electrical work is completed, the washer should be run through
a cycle and checked for water leaks and proper functioning.