3. Technical data

Power:

max. 500 W

Dimensions:

180 x 140 x 130 mm

³

Stand:

250 mm

Holding bracket:

140 x 110 mm²


4. Initial commissioning

Fitting the tube

Remove the screw from the protective glass
cover. Open the glass cover.

Use a clean, dry cloth to fix the new tube into
the spring loaded connection of the tube
holder.

Carefully place the unconnected end of the
tube into the opposite holder.

Make sure that the tube is fitted properly!

Replace the protective glass cover and secure it
with the screw.

Make sure that the sealings fit properly.


5. Operation

Use the stand or the holding bracket to mount
or set up the halogen lamp.

Connect the lamp to the mains.

Pull out the plug to switch off the lamp.


6. Replacing the tube

Replacement tube

U8476714

Pull out the mains plug.

Allow the halogen lamp to cool.

Remove the screw from the protective glass
cover. Open the glass cover.

To remove the tube, use a cloth or similar
material. Do not touch the tube with the bare
hand.

Remove the old tube and replace it with a new
one.

Caution:

Tubes are not to be disposed of together with
domestic waste.

Adhere to the waste disposal regulations for
respective countries.