7.11 Printed Circuit Board (Stepless)
Figure 20. Circuit board (Stepless)
Table 5. Printed Circuit Board (Stepless)
ITEM
DESCRIPTION
HOIST SUPPLY
L1
HOIST POWER SUPPLY – (X22-1)
L2
HOIST POWER SUPPLY – (X22-2)
L3
HOIST POWER SUPPLY – (X22-3)
1U
MOTOR SUPPLY
1V
MOTOR SUPPLY
1W
MOTOR SUPPLY
GROUND WIRES
PE
GROUND TERMINAL, 4 CONNECTIONS: MOTOR, INVERTER, TROLLEY
CONNECTION (X24-9), POWER SUPPLY (X22-9)
TROLLEY CONNECTION
X24
TROLLEY PLUG CONNECTION
L01
ELECTRIC TROLLEY SUPPLY (X24-6)
L02
ELECTRIC TROLLEY SUPPLY (X24-7)
L03
ELECTRIC TROLLEY SUPPLY (X24-8)
PRINTED CIRCUIT BOARD - TROLLEY
6 – D1
RIGHT (X24-5)
7 – D2
LEFT (X24-4)
8 – F
ACCELERATION (HIGH SPEED) (X24-3)
9 – 0 V
COMMON (X24-1)
10 – 48 V
CONTROL POWER SUPPLY (X24-2)
PRINTED CIRCUIT BOARD – CONTROL BOX
10
CONTROL POWER SUPPLY (X23-1)
1
LIFTING (X23-2)
4
LOWERING (X23-3)
-
HIGH SPEED (INVERTER) (X23-4)
-
EMERGENCY STOP (CONTACTOR K10) (X23-5)
X22
X24
X23
T100
K10
A1