1-1 General Specifications
•
All push button clamp multimeter without rotary switch, more safe and
convenient for operation.
•
LCD display digits:
3999 digit large scale LCD readout
•
Measuring rate:
5 times / sec.
•
Over range display
: OL as over range indication
•
Auto power off with audible alert and disable function
•
Full Icon display with backlight
•
Automatic power off time
: Approximately 15 minutes after power on.
•
Conductor Jaws open up to 42mm
•
Low battery indicator:
is displayed. Replace the battery when the indicator
appears in the display
•
Power requirement:
3V battery.
1-2 Environmental Conditions
• Indoor Use
• Calibration: One year calibration cycle.
• Operating temperature:
0°C ~ 30°C ( 80% RH)
≦
30°C ~ 40°C ( 75% RH)
≦
40°C ~ 50°C ( 45%RH)
≦
• Storage temperature:
-20 to +60°C, 0 to 80% RH (batteries not fitted).
• Operating altitude: 2000m (6562 ft)
• Overvoltage category: IEC 61010-1 600V CAT. ,
Ⅲ
CAT. equipment is designed to
Ⅲ
protect against the transients in the equipment
in fixed installations, such as distribution panels, feeders and short branch
circuits and lighting systems in large buildings.
• Conductor Size: 42mm diameter.
• Pollution degree: 2
• EMC: EN 61326-1
• Shock vibration: Sinusoidal vibration per MIL-T-28800E (5 ~ 55 Hz, 3g
maximum).
1