MAX Power CT100 Electric Tunnel Thruster Serials: > 83338 User Manual
Page 7
Manual CT100 & CT125
May 2008
www.max-power.com 6
Thruster motor power supply (12 V / 24 V):
These values are given as an indication, assuming that the batteries are charged at
100% and in charge, that is either 13.8V or 25.4V.
The performance data of the is measured with an approx. consumption of 680A and 11V
for the CT100, or 430A and 22V for the CT125, at the motor’s connections.
Please refer to the characteristics given by the manufacturer of the batteries that will be
used (see section 9 “Batteries”).
Power wiring:
Measure the shortest and most direct route possible between the battery(ies) and the
electric motor; remembering to allow for both “positive and negative” cables.
Recommended cable sections:
Cable lengths
CT100 12V
CT125 24 V
L ≤ 5 m (2,5 x 2)
70mm²
50mm²
5< L ≤ 10 m (5 x 2)
100mm²
70mm²
10 < L ≤ 15 m (7,5 x 2)
150mm²
95mm²
15< L ≤ 20 m (10 x 2)
200mm²
120mm²
For all connections, use appropriate terminals for the cable sections chosen.
It is possible to reduce the cable section to facilitate easy connection but only over a
short distance.
In this case, appropriated crimp fittings should be used at the
connections.
Please consult the "Electrical installation" diagram p. 11 for more information
8. MAIN
POWER
FUSE
Fuse sizes for overcurrent protection are to be determined on the basis of the cable
sections in the circuit and NOT the amperage drawn by the appliance (thruster motor) in
the circuit.
Thruster
Maximum Amperage
Max Power Fuse size
CT100 / 12V
550A
315
CT125 / 24V
330A
200A
9. BATTERIES
Thrusters are high amperage consumers with instantaneous demands, thus, we
recommend you use maintenance-free “starting” type batteries, with high CCA outputs.
For example: Exide Maxxima 900, 12V, capacity 55Ah / starting current 800CCA.
10. ELECTRONIC CONTROL BOX
Install a fused circuit breaker / switch in the boat's main DC distribution panel marked
BOW THRUSTER.
This circuit breaker / switch should ideally be supplied from a different battery bank to the
one used for powering the thruster.
The installer must protect the positive supply cable of the thruster’s control box by means
of a 8A fuse. The size of the power cables (red & black) depends on the length of the