beautypg.com

MAX Power CT100 Electric Tunnel Thruster Serials: > 83338 User Manual

Page 16

background image

Manual CT100 & CT125

May 2008

www.max-power.com 15

23. TROUBLESHOOTING GUIDE

Before contacting your nearest Max Power distributor, please check the below
troubleshooting guide.

Problem

Check

The control panel does not light
up

• Check the 6 wire connector behind the joystick
• Check the thruster's electronic control box 6 wire

connector

• Check the circuit breaker / switch in the boat's

main DC distribution panel

• Check the control box's power fuse (8 A)

The relays are clicking but the
motor is not running

Check the motor's power fuse

Check the main battery isolator

Check the internal relay contacts

Check battery conditions and connections


The motor is running but the
thruster is not working

• Check the propellers are fitted
• Check the motor / drive leg assembly
• Check that the tunnel is not obstructed or the

propellers blocked


The thruster lacks power

• Check the propellers are fitted
• Check the size of the batteries
• Check the batteries are sufficiently charged
• Check the connections are tightened correctly

Check the power cables sections

(See p. 6 : Recommended cable sections)

24. WORLDWIDE DISTRIBUTION NETWORK

To locate the nearest Max Power distributor, please consult the section

"Worldwide Distribution" on our website:

www.max-power.com