Trouble shooting, Specifications – PowerWalker AVR 600 User Manual
Page 5
6. Trouble Shooting
Before using the product, please be sure that Power LED is on. If the Power LED is not on, please
check the following steps:
1. Check if the mains is normal.
2. Check if the power cord is connected firmly.
3. Check if the connected devices are connected to the unit firmly.
4. Check if the unit is turned on.
Problem
Possible Cause
Solutions
Circuit breaker is
“tripped”.
The unit is overload.
Remove some loads first. Reset the circuit
breaker by pressing the button again.
The unit is turned off
automatically and the
Power LED is not lit.
The unit is over-heated. It’s
internal protected function.
Remove some loads and wait until the unit
is cool. Then turn on the unit again.
7. Specifications
Model
AVR 600
AVR 1000
AVR 1200
CAPACITY
600VA / 360W
1000VA / 600W
1200VA / 720W
Input Voltage
220VAC
Input Voltage Range
180 - 264VAC
Input Frequency
50Hz
Voltage Regulation
+/-12%
Output AVR
+/-8%
INDICATOR
Power LED
Green lighting
Boost/Buck LED
Red lighting
PROTECTION
Comprehensive
Protection
Short circuit, overload, and over-temperature protection
PHYSICAL
Dimension (DxWxH)
166mm x 161mm x 86.7mm
Net Weight (kgs)
1.7
2.0
2.1
Environment
Humidity
0-90% RH @ 0-40° C (non-condensing)
Noise Level
Less than 40dB
EN