9

Problem

Cause

Action

Unit will not turn on

(no power LED indicator)

BAT+wirenotconnectedorincorrectvoltage
REMwirenotconnectedorincorrectvoltage

Checkconnectionsforpropervoltage
(11~16VDC)

GND wire not connected

Checkconnectiontoground

Fuse(s)blown

Replacefuse(s)

Unit has power - LED is 

green (but no sound)

Volume turned all the way down

Increasevolumelevelatheadunit

Speakerdefectiveordamaged

Check/replacespeaker

Input signal not connected

Checkhighorlowlevelinputsfor
proper connection

Unit blows fuse(s)

Incorrect fuse rating

Usefuse(s)withcorrectrating

BAT+ wire touching chassis ground

Checkforpinchedwire

Speakerdefectiveordamaged

Check/replacespeaker

Engine noise

Bad ground connection

Makesureamplifierisgroundedto
clean bare metal

SignalgroundlooporRFI(radiofrequency
interference)

Re-routeRCAcablesfromexisting
high current wiring

Distorted audio output

Incorrect input signal type or
inputleveltoohigh

Checkconnectionsandreduce/adjust
inputlevel

Low audio output

Incorrect input signal type or
inputleveltoolow

Checkconnectionsandincreaseor
adjustinputlevel

Weak bass

Lowfrequencyoutputisoutofphase

Adjust phase control as needed

Troubleshooting

OPERATION

Please keep your original sales receipt and be prepared to
providethisreceiptintheeventyourequireservice,asyour
original receipt is considered the best proof of purchase and
indicates the date you purchased your Dual product.

Dealer Name

Dealer Phone

Purchase Date

Registeryourproductonlineatwww.dualav.com.

Registration

For Your Records

Register Your Product