beautypg.com

Typical operating characteristics, Electrical characteristics (continued) – Rainbow Electronics MAX1563 User Manual

Page 4

background image

MAX1562/MAX1562H/MAX1563

Programmable 4A USB Current-Limited
Switches with Autoreset and Fault Blanking

4

_______________________________________________________________________________________

ELECTRICAL CHARACTERISTICS (continued)

(V

IN

= +5V, C

IN

= 1µF, C

OUT

= 4.7µF, T

A

= -40°C to +85°C, unless otherwise noted.) (Note 2)

PARAMETER

SYM B O L CONDITIONS

MIN

TYP

MAX

UNITS

Turn-On Delay

t

ON

R

OUT

= 2

Ω, C

OUT

= 4.7µF

(from ON to 10% of V

OUT

)

0.5

4.0

ms

Turn-Off Delay

t

OFF

R

OUT

= 2

Ω, C

OUT

= 4.7µF

(from ON to 90% of V

OUT

)

3

ms

ON, ON, SEL Input High Level

V

IH

V

IN

= +4V to +5.5V

2

V

ON, ON, SEL Input Low Level

V

IL

V

IN

= +4V to +5.5V

0.8

V

ON, ON, SEL Input
Leakage Current

-1

+1

µA

FAULT Output Low Voltage

V

OL

I

SINK

= 1mA, V

IN

= +4V

0.4

V

FAULT Output
High Leakage Current

V

IN

= V

FAULT

= +5.5V

1

µA

OUT Autoreset Current

In latched-off state, V

OUT

= 0

10

45

mA

OUT Autoreset Threshold

In latched-off state, OUT rising

0.35

0.65

V

OUT Autoreset Blanking Time

In latched-off state, V

OUT

> 0.5V

10

35

ms

Note 1: Short-circuit detect threshold is the output voltage at which the device transitions from short-circuit current limit to continuous

current limit.

Note 2: Specifications to -40°C are guaranteed by design, not production tested.

SUPPLY CURRENT vs. SUPPLY VOLTAGE

MAX1562 toc01

SUPPLY VOLTAGE (V)

SUPPLY CURRENT (

µ

A)

5.0

4.5

4.0

3.5

5

10

15

20

25

30

35

40

45

50

0

3.0

5.5

TEMP = +25

°C

TEMP = -40

°C

TEMP = +85

°C

SHUTDOWN CURRENT
vs. SUPPLY VOLTAGE

MAX1562 toc02

SUPPLY VOLTAGE (V)

SHUTDOWN CURRENT (

µ

A)

5.0

4.5

4.0

3.5

0.5

1.0

1.5

2.0

2.5

3.0

3.5

0

3.0

5.5

TEMP = +25

°C

TEMP = -40

°C

TEMP = +85

°C

V

ON

= 5V

SWITCH-OFF LEAKAGE CURRENT

vs. TEMPERATURE

MAX1562 toc03

TEMPERATURE (

°C)

SWITCH-OFF LEAKAGE CURRENT (nA)

60

35

10

-15

0.01

0.1

1

10

100

1000

0.001

-40

85

Typical Operating Characteristics

(V

IN

= +5V, C

IN

= 1µF, C

OUT

= 4.7µF, T

A

= +25°C, unless otherwise noted.)