Multichannel remote/local temperature sensors, Table 8. slave address decoding (add0 and add1) – Rainbow Electronics MAX1989 User Manual
Page 15

MAX1668/MAX1805/MAX1989
†
Multichannel Remote/Local
Temperature Sensors
______________________________________________________________________________________
15
Figure 5. SMBus Write Timing Diagram
Figure 4. SMBus Read Timing Diagram
SMBCLK
A = START CONDITION
B = MSB OF ADDRESS CLOCKED INTO SLAVE
C = LSB OF ADDRESS CLOCKED INTO SLAVE
D = R/W BIT CLOCKED INTO SLAVE
A
B
C
D
E
F
G
H
I
J
SMBDATA
t
SU:STA
t
HD:STA
t
LOW
t
HIGH
t
SU:DAT
t
SU:STO
t
BUF
K
E = SLAVE PULLS SMBDATA LINE LOW
F = ACKNOWLEDGE BIT CLOCKED INTO MASTER
G = MSB OF DATA CLOCKED INTO MASTER
H = LSB OF DATA CLOCKED INTO MASTER
I = ACKNOWLEDGE CLOCK PULSE
J = STOP CONDITION
K = NEW START CONDITION
SMBCLK
A
B
C
D
E
F
G
H
I
J
K
SMBDATA
t
SU:STA
t
HD:STA
t
LOW
t
HIGH
t
SU:DAT
t
HD:DAT
t
SU:STO
t
BUF
A = START CONDITION
B = MSB OF ADDRESS CLOCKED INTO SLAVE
C = LSB OF ADDRESS CLOCKED INTO SLAVE
D = R/W BIT CLOCKED INTO SLAVE
E = SLAVE PULLS SMBDATA LINE LOW
L
M
F = ACKNOWLEDGE BIT CLOCKED INTO MASTER
G = MSB OF DATA CLOCKED INTO SLAVE
H = LSB OF DATA CLOCKED INTO SLAVE
I = SLAVE PULLS SMBDATA LINE LOW
J = ACKNOWLEDGE CLOCKED INTO MASTER
K = ACKNOWLEDGE CLOCK PULSE
L = STOP CONDITION, DATA EXECUTED BY SLAVE
M = NEW START CONDITION
Table 8. Slave Address Decoding (ADD0
and ADD1)
Note: High-Z means that the pin is left unconnected and floating.
0011 001
High-Z
GND
0011 000
ADDRESS
0101 001
GND
High-Z
0011 010
V
CC
GND
0101 011
V
CC
High-Z
0101 010
1001 101
High-Z
V
CC
1001 100
GND
GND
GND
V
CC
High-Z
High-Z
1001 110
V
CC
V
CC
ADD0