beautypg.com

Typical operating characteristics, Electrical characteristics (continued) – Rainbow Electronics MAX608 User Manual

Page 3

background image

MAX608

5V or Adjustable, Low-Voltage,

Step-Up DC-DC Controller

_______________________________________________________________________________________

3

0

50

100

150

200

SUPPLY CURRENT

vs. INPUT VOLTAGE

INPUT VOLTAGE (V)

SUPPLY CURRENT (

µ

A)

0

1

2

3

4

5

MAX608-06

60

1

10

100

1000

EFFICIENCY vs. LOAD CURRENT

(V

OUT

= 12V)

70

80

90

100

MAX608-02

LOAD CURRENT (mA)

EFFICIENCY (%)

V

IN

= 6.0V

V

IN

= 5.0V

V

IN

= 3.0V

V

IN

= 9.0V

V

IN

= 2.0V

60

1

10

100

1000

EFFICIENCY vs. LOAD CURRENT

(V

OUT

= 3.3V)

70

80

90

100

MAX608-03

LOAD CURRENT (mA)

EFFICIENCY (%)

V

IN

= 2.0V

V

IN

= 3.0V

60

1

10

100

1000

EFFICIENCY vs. LOAD CURRENT

(V

OUT

= 5V)

70

80

90

100

MAX608-01

LOAD CURRENT (mA)

EFFICIENCY (%)

V

IN

= 4.0V

V

IN

= 3.5V

V

IN

= 3.0V

V

IN

= 2.0V

0

700

600

500

400

300

200

100

LOAD CURRENT vs.

MINIMUM START-UP

INPUT VOLTAGE

MAX608-04

MINIMUM START-UP VOLTAGE (V)

LOAD CURRENT (mA)

1.8

2.2

2.6

3.0

3.4

3.8

4.0

V

OUT

= 5V

CIRCUIT OF FIGURE 2a
EXTERNAL FET THRESHOLD LIMITS
FULL-LOAD START-UP BELOW 3.7V

0

500

400

300

200

100

LOAD CURRENT vs.

MINIMUM START-UP

INPUT VOLTAGE

MINIMUM START-UP VOLTAGE (V)

LOAD CURRENT (mA)

MAX608-05

V

OUT

= 12V

CIRCUIT OF FIGURE 2b
EXTERNAL FET THRESHOLD LIMITS
FULL-LOAD START-UP BELOW 3.6V

1.8

2.2

2.6

3.0

3.4

3.8

4.0

ELECTRICAL CHARACTERISTICS (continued)

(V

OUT

= 5V, I

LOAD

= 0mA, T

A

= -40°C to +85°C where indicated. T

A

= -25°C to +85°C for all other limits. Typical values are at

T

A

= +25°C.)

PARAMETER

SYMBOL

CONDITIONS

MIN

TYP

MAX

UNITS

Current-Limit Trip Level

V

CS

V

OUT

= 3V to 16.5V

85

100

115

mV

CS Input Current

I

CS

0.01

±1

µ

A

EXT Rise Time

V

OUT

= 5V, 1nF from EXT to GND

50

ns

EXT Fall Time

V

OUT

= 5V, 1nF from EXT to GND

50

Note 1:

Limits over this temperature range are guaranteed by design.

Note 2:

The MAX608 must be operated in bootstrapped mode with OUT connected to the DC-DC circuit output. The minimum output

voltage set point is +3V.

Note 3:

Output voltage guaranteed using preset voltages. See Figures 4a–4d for output current capability versus input voltage.

Note 4:

Output voltage line and load regulation depend on external circuit components.

Note 5:

Operation in the external-feedback mode is guaranteed to be accurate to the V

FB

trip level, and does not include resistor tolerance.

80

120

__________________________________________Typical Operating Characteristics

(T

A

= +25°C, unless otherwise noted.)

T

A

= -40°C to +85°C (Note 1)

EXT On-Resistance

EXT = high or low

15

30

T

A

= -25°C to +85°C