As a result, the analog input impedance is relatively
constant over the input voltage as shown in Figure 5.

Single-ended conversions are internally referenced to
AGND1 (Tables 3 and 4). In differential mode, IN+ and
IN- are selected according to Tables 3 and 5. When con-
figuring differential channels, the differential pair follows
the analog configuration byte for the positive channel.
For example, to configure CH2 and CH3 for a ±V

REF

dif-

ferential conversion, set the CH2 analog configuration
byte for a differential conversion with the ±V

REF

range

(1010 1100). To initiate a conversion for the CH2 and
CH3 differential pair, issue the command 1010 0000.

Analog Input Bandwidth

The MAX1302/MAX1303 input-tracking circuitry has a
1.5MHz small-signal bandwidth. The 1.5MHz input band-
width makes it possible to digitize high-speed transient
events. Harmonic distortion increases when digitizing
signal frequencies above 15kHz as shown in the THD, -
SFDR vs. Analog Input Frequency plot in the Typical
Operating Characteristics
.

Analog Input Range and Fault Tolerance

Figure 7 illustrates the software-selectable single-
ended analog input voltage range that produces a valid
digital output. Each analog input channel can be inde-
pendently programmed to one of seven single-ended
input ranges by setting the R[2:0] control bits with
DIF/SGL = 0.

MAX1302/MAX1303

8-/4-Channel, ±V

REF

Multirange Inputs,

Serial 16-Bit ADCs

______________________________________________________________________________________

15

CS

SCLK

1

2

3

4

5

6

7

8

9

10

11

12

13

14

15

16

17

18

19

20

21

22

23

24

25

26

27

28

29

30

31

32

DIN

S

C2

C1

C0

0

0

0

0

ANALOG INPUT

TRACK AND HOLD*

DOUT

B15

B14

B13

B12

B11

B10

B9

B8

B7

B6

B5

B4

B3

B2

B1

B0

BYTE 1

BYTE 2

BYTE 3

BYTE 4

SSTRB

HOLD

TRACK

HOLD

HIGH

IMPEDANCE

t

ACQ

HIGH

IMPEDANCE

*TRACK AND HOLD TIMING IS CONTROLLED BY SCLK.

f

SAMPLE

≈ f

SCLK

/ 32

SAMPLING INSTANT

Figure 2. External Clock-Mode Conversion (Mode 0)